Section 7-3-3
7-3-3 Brake roller replacement
Refer to Section 7-3-1 for the specification of the Brake roller.
(1)
Remove any documents from the ADF paper chute (Chuter Unit).
(2)
Open the ADF by pulling the ADF open level and turning the ADFF cover to the front.
Be careful, the ADF cover may close and pinch your finger.
(3)
Remove the Brake roller from the scanner.
1) Grab both sides of the Brake roller cover, and press to the inside and pull down (towards you), as shown in the
illustration below.
2) Lift up the right side of the Brake roller and remove the right shaft. Then pull the left shaft out of its hole to remove
it.
(4)
Remove the Brake roller from the shaft.