G 03886- Edition 04 - August 12
3/3
B 10
Unpacking / Handling / Storage
Handling
Regarding its weight, handling the pump can cause muscle strain or back
injury. For all equipment handling, use the appropriate handling devices.
Handling the pump to
remove it from the crate
Prepare the pump
It is highly recommended that a
hoist is used for lifting with the
following specifications:
Length for each arm must be
> 500 mm
(21.65 inch).
Rated capacity for each arm
must be
> 350 kg
(772 lbs).
Pump
Weight (lbs/kg)
A 203H
584
/
265
A803H
848 /
385
A1503H
1201 /
545
A1803H
1201 /
545
Fit the hoisting rings (delivered in
the crate in separate packaging)
in the appropriate holes.
With a hoist and a sling with three arms,
lift the pump using hoisting rings.
Screw in the leveling pads of the frame and lower the pump on the
wheels. Remove any additional packages from the crate and set
aside.
These packages will contain cables, accessories, and so forth.
WARNING
HEAVY OBJET
Can cause muscle strain or back injury.
Use lifting aids and proper lifting techniques
when removing or replacing.
Hook
Hoisting
ring
Heavy product
This product needs special handling precautions due to its weight. It should
be removed from its crate only by staff trained in heavy materials
handling : use the lifting rings and devices provided with the product. The
maker can not be held liable for the consequences of using other rings.
In order to prevent moisture from entering the pump before installation,
it has been pressurized before shipment with nitrogen and sealed with
blanking plates. Do not remove these blanking plates until you are ready
to install the product on your vacuum system.
adixen Vacuum Products - A3H Series Operating instructions