M4 monitoring system function table
G 03902 - Edition 05 - August 12
DEFINITION MENU
Selection
Choice
Description
Initial
configuration
LANGUAGE
ENGLISH
FRENCH
All the menus are in the selected language.
ENGLISH
SYSTEM SELECT
A203H
A803H
A1503H
A1803H
A803H_C
Select the pump monitored by the monitoring
system.
(“c” indicates that the Roots is fitted with frequency
convertor option)
According
to the
pump
ROOTS 2
(3)
ENABLED
DISABLED
Allows to manage a second Roots in case of
integration in a dry pumping system.
This parameter must be set on disabled for A3H
pumps only.
DISABLED
ANALOG INPUT
(1)
ENABLED
DISABLED
Allows to monitor an 0-10V analog input with two
threshold.
DISABLED
Li1 LOG INPUT
(2)
ENABLED
DISABLED
Allows retrieving logic data on Li1 LOG input using
a customer supplied sensor (closed when switched
off).
DISABLED
Li3 LOG INPUT
(2)
ENABLED
DISABLED
Allows retrieving logic data on Li3 LOG input using
a customer supplied sensor (opened when switched
off).
DISABLED
AUTO START
ENABLED
DISABLED
Allows the pump to restart automatically after a
power cut, irrespective of the duration.
DISABLED
ROOTS CMD
ENABLED
DISABLED
Allows separate control of the Roots START/
STOP control from the FB START/STOP, instead of
simultaneous start-up, the Roots is started using
ROOTS
key or remote controlled.
DISABLED
PURGE CMD.
ENABLED
DISABLED
Allows independant purge control at pump start-up.
The purge flow is controlled by the
PURGE
key or
remote controlled.
This menu appears when the coding wheel is position
to 1 (initial configuration, coding wheel to 0).
DISABLED
N2 STAND BY
ENABLED
DISABLED
“Standby purge“ option validation during
equipment standby phase.
DISABLED
INLET VALVE OPTION
ENABLED
DISABLED
Inlet valve presence validation.
DISABLED
BACKUP POW. OPTION
ENABLED
DISABLED
“Power failure protection” option presence
validation.
DISABLED
BUZZER
ENABLED
DISABLED
Buzzer validation in case of defect. Buzzer stops by
pressing on
ENTER
.
ENABLED
(1) Only on A203H pump model.
(2) Li1 LOG, Li3 LOG correspond to the logic sensors connected at the rear of the M4 monitoring
(3) Only on A1503H / A1803H
SET
ENTER
ENTER
adixen Vacuum Products - A3H Series Operating instructions