Filling the machine oil housings
Mineral and synthetic oils cannot be used together. Contact the manufacturer
or your service agent before making any changes.
The pumps are tested using synthetic fluid A113. We recommend the
exclusive use of this fluid.
The safety data sheet for oil is available on our website
www.adiden.com.
Pump
model
Quantities (liter)
Nber of
can 0.4 L
FB203
Roots housing
Oil capa-
city
gear side
motor side
A203H
0.35
-
-
0.35
x 1
A803H
0.35
0.45
0.25
1.05
x 3
A1503H
0.35
1.00
0.55
1.90
x 5
A1803H
0.35
1.00
0.55
1.90
x 5
Note : on A803H, the Roots oil casings are filled at factory.
Oil quantities
Risk of oil ingestion.
The pumps are delivered without an oil charge: the oil is delivered in
separate containers.
Wear gloves, protective glasses and mask to fill in the oil in the pumps.