4/4
C 43
Use of the M4 monitoring system for
pumping operation
G 03903 - Edition 04 - August 12
Use with two HHR
To take the control with a HHR, press only on the
CONTROL
key of
the chosen HHR : then a star and a “X” flash alternatively on the
left corner of the display.
The control of the pump is now not possible
from the other
HHR, as long as the first one has not given the control back.
To give the control again, press on the
CONTROL
key of the HHR,
until the star has disappeared.
Reading of data and parameters can be done on both HHR,
even if
they do not control the pump
.
If the message ”NOT ALLOWED” appears after an action of any key, it means
that the HHR has not taken the control.
Press CONTROL key, check the presence of the star and the letter “X”
alternavely on the left corner of the screen, showing that the control has
been taken.
When the pump has been configurated for automatic restart after a power
failure, it is the responsibility of the user to take all the measures required to
prevent risks resulting from this type of operation.
Auto-restart
configuration
In standard configuration (factory configuration), when there is a loss
of voltage, system is stopped. When the voltage comes back, to restart
the system, it is necessary to press
START
.
The automatic restarting is possible if
AUTO RESTART
is set on
ENABLED.
Start-up after an
emergency stop
To restart the pump after an emergency stop, it is necessary to:
remedy to the problem,
rotate to unlock the emergency button,
press the
“START”
button.
–
–
–
adixen Vacuum Products - A3H Series Operating instructions