Installation, Operation and Maintenance Manual

Steambath Generator Systems

Residential Models: MX4E-6E

mr

.

steam

®      

l

Feel Good Inc.

® 

Installation, Operation & Maintenance Manual 

AromaSteam

Fragrance Metering

 Pump

 for

 

Residential and Day Spa Steam Rooms

Part Number MS AROMA (

104496

)

__________________________________

IMPORTANT: 

 Leave this material with the home owner.

__________________________________ 

Содержание mr. steam AromaSteam MS AROMA

Страница 1: ...e Manual Steambath Generator Systems Residential Models MX4E 6E mr steam l Feel Good Inc Installation Operation Maintenance Manual AromaSteam Fragrance Metering Pump for Residential and Day Spa Steam Rooms Part Number MS AROMA 104496 __________________________________ IMPORTANT Leave this material with the home owner __________________________________ ...

Страница 2: ...r installation leave this document with the homeowner Do not discard this document The information in this manual should be used in conjunction with consultations with an architect designer and contractor in determining factors necessary in providing a suitable and safe steam room The MrSteam AromaSteam is intended to be operated with MrSteam iSteam AirTempo or iTempoPlus controls only The control...

Страница 3: ...System for Residential and Day Spa Steam Rooms Part Number MS AROMA 120V This installation operation and maintenance manual is for general reference The installation operation and maintenance manual supplied with the product must be used for installation operation and maintenance purposes Failure to use the installation operation and maintenance manual supplied may result in a property damage or p...

Страница 4: ...e into a typical sized residential or Day Spa steam room Start with the AromaSteam volume at a very low setting Gradually increase the volume setting until a comfortable fragrance level is reached Do not exceed the Recommended Setting indicated on the AromaSteam volume Do Not alter or modify any MrSteam product Doing so may result in a personal injury Discontinue use of the steam generator and con...

Страница 5: ...monitor the consumption of fragrance and for easy replacement 3 The AromaSteam should not be installed in areas accessible to children A locked room is strongly recommended i e utility room 4 The AromaSteam is designed and intended for indoor use only and is to be located indoors in a dry clean location and not subject to moisture condensation or similar high humidity environments 5 Do not install...

Страница 6: ...awings for Illustrative Purposes Only AromaSteam Overview AromaSteam Pump AromaSteam Transformer 120VAC 240VAC Typical MrSteam Steam Generator shown with cover removed Steam Generator Printed Circuit Board Request Cable Pressure Hose Steam Head Steam Line 90 T Check Valve Receptacle required ...

Страница 7: ...ck Valve Pressure Hose 6ft Steam Generator Steam Pipe 90 T Suction Hose AromaSteam Transformer 120VAC 240VAC 4 1 2 ft To Outlet Request Cable 6ft To Steam Generator AromaSteam Pump 5 10ft Optimal Fragrance Container AromaSteam Pump Specs Dimensions 4 3 W x 14 8 H x 5 4 D Weight 5 pounds Supply Voltage 120VAC 240VAC 50 60 Hz Max Current Draw 0 1 Amps General System Dimensions AROMASTEAM ...

Страница 8: ...a where the ambient temperature does not exceed 88o F 8 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions All Drawings for Illustrative Purposes Only Tools required Cordless drill with a Phillips bit Level Use only non sparking tools Take precautionary measures against static discharge Mounting the AromaSteam on a Wall 1 Pre drill as required and install the two sc...

Страница 9: ... Operation and Installation Instructions All Drawings for Illustrative Purposes Only Drill Template IMPORTANT NOTE Do no scale template Template must be printed at 1 1 scale WARNING Failure to print template at 1 1 scale will result in wrong mounting hole locations ...

Страница 10: ...om to download this document Install Check Valve into 90 T adaptor Failure to install the supplied Check Valve may result in excessive fragrance delivery into the steam room and cause dizziness and or personal injury The supplied Check Valve prevents excessive amounts of fragrance from entering the steam line and steam room Never install the AromaSteam without the supplied Check Valve 10 I N S T A...

Страница 11: ...fragrance container are seated in rectangular openings on the bottom of the AromaSteam 4 Insert the fragrance container with its label facing outward so it is visible at all times This label contains important information Bottom Diagram IMPORTANT NOTE To prevent damage do not use tools to tighten the container cap 11 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instruction...

Страница 12: ...hafing 4 Locate the two quick connect tabs labeled AROMA on the printed circuit board in the location shown 5 Connect the request cable to the terminals The terminals are not polarized 6 Connect AromaSteam s transformer into a 120VAC 240VAC wall outlet I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions AromaSteam Connections Steam Generator Circuit Board AromaSteam ...

Страница 13: ...d location of 900 T IMPORTANT NOTE If liquid is not filling tubing in AromaSteam head release priming button and check if suction hose is securely installed onto barb fitting below AromaSteam head and check valve IMPORTANT NOTE If an extended pressure hose is needed please contact MrSteam Technical Service 13 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions Steam ...

Страница 14: ...ped into the steam line at preset intervals Activating the AromaSteam from an iSteamX Control 1 Press the START button to turn the steam generator on 2 In the dashboard press the AromaSteam icon flower on the left then press the On Button to start or Off button to stop 3 Aroma fragrance will automatically be pumped into the steam line at preset intervals Activating the AromaSteam from iTempo Plus ...

Страница 15: ...h the Check Valve when the AromaSteam is energized Apply compressed air through the Check Valve Attach the compressed air at the point of connection of the pressure hose 8 Ensure the AromaSteam has been powered up AromaSteam fragrance delivery too much or too little The AromaSteam has been factory set to deliver a suitable amount of aromatic fragrance into a typical sized steam room Please contact...

Страница 16: ...04255 AromaSteam Transformer 120VAC 240VAC 104494 Replacement Parts This AromaSteam is factory wired If the power cord of the AromaSteam is damaged it must be replaced by the MrSteam service department or similarly qualified personnel in order to avoid an electric shock hazard All electrical connections to be made by a licensed qualified electrician Disconnect all power to the steam generator befo...

Страница 17: ...ose and sinuses The Safety Data Sheet provides comprehensive information about MrSteam Aroma fragrances Contact 1 800 767 8326 or go online at www mrsteam com for a copy of the Safety Data Sheet MrSteam Aroma Fragrances MS OIL 1 5 READ ME FIRST Warning As you follow these instructions you will notice warning and caution symbols This blocked information is important for the safe and efficient insta...

Страница 18: ...ith room construction materials Do Not alter or modify any MrSteam product Doing so will void the warranty MrSteam Aroma fragrances must be disposed of as hazardous waste Avoid fragrance contact with eyes May cause mild eye irritation Ingestion may cause irritation nausea vomiting Fragrance vapors may cause drowsiness allergic reactions difficulty breathing or skin irritation If condition persists...

Страница 19: ...ture does not exceed 88 o F Using a fragrance container that is not secured in the AromaSteam or using a AromaSteam that is not mounted may result in spillage excessively strong vapors or a fire hazard 6 Insert the fragrance container with the label facing outward so it is visible through the AromaSteam The label contains important information 7 Always keep the container in the AromaSteam while it...

Страница 20: ...e steam line at preset intervals AromaSteam Button chroma time temp aroma AromaSteam Button OPERATION cont mr steam Feel Good Inc PUR103938 REV 2 22 2023 Mr Steam and des AirTempo AromaFlo AutoFlush AutoSteam AudioWizard Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Spa HomeWizard iButler iTempo iTempo Plus iGenie iSizing iSteam Linear Stea...