Diagram 3
Diagram 4
Diagram 1
Diagram 2
Installing the AromaSteam
Locating the AromaSteam:
1. Place in a location that allows visual monitoring of the fragrances
level.
2. Place in a location that allows for easy replacement of the
fragrance container.
3. Locate the AromaSteam within 6' of the steam generator as
required to route the request cable in a safe and secure
manner. See the system dimensions on page 7.
4. Locate the AromaSteam within 4' of a grounded outlet as
required to route the electrical cord in a safe and secure
manner. See the system dimensions on page 7.
5. Locate the AromaSteam within 6' of the steam supply line as
required to route the pressure hose in a safe and secure
manner. See the system dimensions on page 7.
6. Do not install in an unheated location where water could
freeze.
7. Locate in a area where the ambient temperature does not
exceed 88
o
F.
8
I N S T A L L E R S E C T I O N
AromaSteam
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Tools required:
• Cordless drill with a Phillips bit
• Level
Use only non-sparking tools. Take pre cautionary measures
against static discharge
Mounting the AromaSteam on a Wall
1. Pre-drill as required and install the two screws provided.
They must be 2 -1/2" inches apart and level as required to
securely mount the AromaSteam keyhole slots. Use Drill
Template on following page if necessary.
2. Use a level to make sure the screws are level.
3. Mount the AromaSteam keyholes onto the screws. Tighten
screws as required to firmly secure the AromaSteam.
4. Use the two mounting screw provided to secure the
AromaSteam using the two mounting hole at the middle of
the AromaSteam (Diagram 3).
5. Use anchors or other hardware as required for secure
mounting. Test the AromaSteam for secure mounting.
Keyhole
slots
Back of Pump
Mounting
Holes
6
11
/
16
"
2
1
/
2
"