200 . Torion T-9 User’s Guide
RIC Graph
- This is the chromatographic trace for selected masses and can be
used to look for a specific peak with a given mass.
Summed Graph -
This is the spectra of a group of chromatographic scans
that have been selected using the average function.
Background Graph
- This is the spectra for a section of selected background.
Differences Graph
- This is the spectra data showing the difference between
the background spectra and the highlighted section of selected spectra.
Overlay
- This is a chromatographic trace of several TICs that have been
selected and are displayed together in the same chart.
Decon Spectra Graph
- This is the spectral graph of the deconvolution peaks.
Library Search Spectra Graph
- This shows the head to tail spectra of an
unknown compound search. The spectra from the library are on the bottom and
the spectra from the analytical run are on top.
Manual Integration Graph
- This graph shows the manually integrated value
of a specific peak.
The charts can be exported as
WMF
,
JPG
,
BMP
, or
CSV
files. One of these options
needs to be selected in the
Export File Type
section.
The
Root Filename
section is for browsing to a location in which to save the files. Click
the
Find…
button to open a Windows browse dialog and select the location where the
image files will be saved after they are created.
The option
Append graph-type suffix
means that the type of graph will be added to
the end of the filename. If a filename were
Sample
it would be exported as
Sample-
tic
, if the file were a TIC file.
The
CSV
data are saved in two columns with the time first and then the response
second. In the case of overlaid TICs the data are in two columns with the starting time
at zero then progressing to the end of the first file. The time then returns to zero and
starts with the data from the next file. This is repeated until all of the files in the overlay
graph have been stored in the
CSV
file. The data can be plotted as one single plot. The
data cannot be easily plotted side by side since the retention time of the data points is
not a fixed time. Therefore each set of data will have different times on the x axis. This
is a result of the dynamic ionization used in the toroidal ion trap.
b)
Show Results from File
- This option will open the data file that was generated on
the Torion T-9 during an analysis.
If there is a report file in the .RES file it will open in Notepad. The image below is an
example of the report.
Содержание TORION T-9
Страница 1: ...TORION T 9 Gas Chromatograph Mass Spectrometer GC MS User s Guide GC MS...
Страница 4: ...iv Torion T 9 User s Guide...
Страница 10: ...6 Torion T 9 User s Guide...
Страница 11: ...1 Introduction...
Страница 15: ...2 Safety Practices...
Страница 24: ...20 Torion T 9 User s Guide...
Страница 31: ...3 System Overview...
Страница 40: ...36 Torion T 9 User s Guide...
Страница 41: ...4 Basic Custodion Operations...
Страница 49: ...5 Basic Operation...
Страница 116: ...112 Torion T 9 User s Guide...
Страница 117: ...6 Software...
Страница 257: ...7 Advanced Operations...
Страница 260: ...256 Torion T 9 User s Guide...
Страница 261: ...8 Maintenance...
Страница 268: ...264 Torion T 9 User s Guide...
Страница 269: ...9 Troubleshooting...