CT/L-14 Controller
35
Types of lock-chambers operated by the
CT/L-14
controller
1. Two-lock lock-chamber is intermediate space with a free passage through two doors. Each
lock-chamber door is operated by two internal and external readers (in regard to the lock-
chamber). Reader can be replaced or duplicated by the RC button (see below the lock-
chamber OD settings). To provide the lock-chamber operation two door sensors are required:
#1 for OD1 and #2 for OD2.
Figure 18. Layout of the lock lock-chamber
2. Rotor turnstile lock-chamber is a
RTD-15
,
RTD-16
,
RTD-20
full-height turnstile with a rotor set
in a lock-chamber mode. Entrance and exit are operated by two internal and external readers
(in regard to the lock-chamber). Reader can be replaced or duplicated by the RC button (see
below the lock-chamber OD settings). For comfort of use in the Web-interface of the controller
the lock-chamber is presented as 4 single-sided locks (OD1 and OD3 for a passage in one
direction through the turnstile, OD2 and OD4 in the opposite direction). To operate the lock-
chamber passageway control sensors are activated: PASS A for the direction of the passage
1, PASS B for the direction of the passage 2.
Figure 19. Layout of the rotor turnstile lock-chamber
3. Turnstile-and-lock lock-chamber is intermediate space between the turnstile and the
intermediate door with a free passage through the zone. The turnstile and door lock are
operated by two internal and external readers each (in regard to the lock-chamber). Reader
can be replaced or duplicated by the RC button or RC (see below the lock-chamber OD