Operation Manual
12
When connecting to RS-485 interface, follow the instructions of the connected device and the
layout presented in Fig. 3. To connect a communication line of RS-485 to the controller, the #2
cable type is to be applied (Table 3).
Following variants of reader connection are possible (Fig. 3):
•
Up to eight
IR03.1
,
IR04.1
,
IR10
card readers
(in any combination).
•
One or two
IR04
,
IRP01
readers (in any combination)
and correspondingly together with up to
seven or six
IR03.1
,
IR04.1
or
IR10
card readers
(in any combination).
•
Up to eight
MR07.1
card readers.
•
Up to
two
IR07
card readers.
•
One or two indication blocks with
AI01
IR-receiver
to any of the above options.
Note:
+ 12V and
XT5
terminal block GND contacts can be used in order to power the readers,
provided that max. load current must not exceed 0.5 A.
When installing readers (card capture readers, indication blocks), different numbers (addresses) are to
be set, otherwise readers with the same addresses will not work. The number (address) is determined
by the state of the “reader number” jumper (jumpers) on the case or on the product board (see the
operational documentation for this product).
5.6.2 Connection to
Wiegand
interface
When using the
AC-03
interface converter, up to four readers with the Wiegand interface can be
connected to the controller, and when using four
AC-02.1
converters, up to 8 readers can be
connected. The connection layout and description of the reader indication in this case are given in
the operational documentation for the interface converter.
Note:
To power the readers, one can use the +12 V and terminal blocks GND contacts of the
AC-03
(
AC-02.1
) interface converter
,
while the total current consumption of the readers must
not exceed 0.5 A.
6 MARKING AND PACKAGING
The marking label of the controller is placed on the back plate of the housing. The marking label
provides following information concerning the controller:
•
trade mark and contact details of the manufacturer;
•
name and number of model;
•
serial number;
•
date and month of manufacture;
•
allowed power voltage range;
•
consumption current.
The controller board contains labels with default MAC-address and IP-address of the controller.
The controller is packed into a paperboard box, preventing it from damages during transportation
and storage.
7 SAFETY REQUIREMENTS
7.1 Installation safety requirements
Installation and technical maintenance of the controller should be performed by qualified staff, after
getting acquainted with the Operation manual and safety rules. Installation should be performed in
accordance with general electrical and work safety rules.