Operation Manual
24
Figure 12. Connection layout of optional equipment to relay outputs
Figure 13. Connection layout of optional equipment to “Open collector” outputs
9 CONFIGURATION
The principal controller configuration (setting the configuration, adding and removing controllers of
the second level and optional readers) is possible only via the controller Web-interface
(Appendix 4).
The controller configuration order:
1 Verify all connections (Sect. 8.2). Connect the power supply to the circuit with voltage and
frequency indicated in its operational documentation. Turn on the power source, the LED
indication is to light up on the controller housing. It means that the controller is switched on.
2 Connect to the controller Web-interface via
Ethernet
network (Appendix 4, p.2).
Note:
The computer should be in the same subnet with the controller. At first turn-on, it might be
necessary to change network settings of the computer. The controller is equipped with IP-
addresses from 10
th
subnet by default. Add IP-address:
10.x.x.x
(x- random numbers)
and subnet mask
255.0.0.0
. to TCP/IP additional settings of the computer. No such
servers or services like DNS and WINS are required. After turn-on network settings of the
controller can be changed to settings recommended by system administrator in the
software or via the Web-interface.