Operation Manual
26
10 UPDATE OF EMBEDDED SOFTWARE
Update the embedded software and format the memory is possible using the controller Web-
interface in the
Diagnostic
section
(Appendix 4, p.9).
11 OPERATION
When operating the controller, follow the safety measures indicated in Sect. 7.2.
After the configuration, the controller can operate in the following modes:
Without connection to the security system server.
If connection to
Ethernet
network and PC is also unavailable, the controller can perform the
following functions:
•
Reads identifiers of the presented cards sent from the reader, and grants or denies access,
depending on their presence in the list.
•
Controls connected ODs.
•
Arms and disarms the protected zone; controls alarm line and ODs in “
Security”
mode;
activates additional outputs in “
Alarm”
mode.
•
Records events in the event log in the controller memory.
•
Supports functions of local location monitoring, T&A and double-check access.
If the controller is connected to the network and other controllers of the system, the function of
global location monitoring is available.
When connected to the security system server.
Besides those that are supported in the stand-alone mode, the following functions are available:
•
Data from event log are automatically transferred to the database on security system server.
•
Availability of verification function depends on installed extensions of network software.
11.1 ACS operating modes
The change of operating mode is carried out by the command of software or Web-interface.
Note:
•
In configuration “
Controller for one two-way lock
” and “
Controller for vehicle
checkpoint
” should be made simultaneously for both directions.
•
Operating mode in “
Controller for turnstile
” configuration versions is to be set
independently for each direction
The following ACM are provided by the controller, that operates as a part of ACS, (ACM indication
is given in the Table 4):
“
Open”
operating mode – free passage mode.
•
OD remains unlocked until the operating mode is changed.
•
Pressing the buttons of RC-panel and RC-button (“
Exit
”) is ignored.
“
Control”
operating mode –
basic operating mode as a part of ACS.
•
OD is locked.
•
When an access granting card is presented to the reader, OD is unlocked for
Holding in
unlocked state period
.
“
Closed”
operating mode –passage denial mode.
•
OD remains locked until the operating mode is changed.
•
Pressing the buttons of RC-panel and RC-button (“
Exit
”) is ignored.
•
When a card is presented, an access violation event is registered.
“
Security”
•
OD remains locked until the operating mode is changed.
•
Pressing the buttons of RC-panel is ignored.
1
Operating mode is available only for “
Controller for the locks
” configuration and for connected
CL-201
lock
controllers.