CT/L-14 Controller Web-Interface
45
3. In the opened window make the necessary changes of the settings:
•
Number
parameter sets the number of the added reader;
•
Communication interface
parameter sets the interface or reader type;
•
Connection port
parameter sets the port of the interface or the address on the bus (RS-
485 / Wiegand);
•
Operating device
parameter sets the number of the OD to which the reader is attached;
•
Direction
parameter sets the direction of the OD to which the reader is attached;
“Morpho” fingerprint scanner:
•
Sensor position
parameter sets the position in which the reader will identify and verify the
finger, taking into account its possible rotation;
•
Possibility of an unauthorized access
parameter sets the probability of unauthorized
access (error of the first kind), expressed as a percentage of the number of access of
unauthorized persons by the system;
•
Fingerprint format
parameter sets fingerprint formats.
Trassir
•
SSL
parameter sets the exchange coding initiation with Trassir server.
•
Address
parameter sets line with Trassir server IP-address.
•
Port
parameter sets Trassir server port number.
•
Password
parameter sets Trassir server authorization password.
•
Movement line
parameter sets the number of the movement line for this OD direction;
•
Channel
parameter
sets
the
line with Trassir server channel ID.
4. To add the reader with the assigned number and transfer the changed parameters to the
controller, click the
Save
button. The
Reader
window will be closed.
5. To exit the window
Reader
without saving changes, click the
Cancel
button. Also, it is possible
to close the window using the
Close
button .
6. In order to delete the reader from the list, click the title bar in the page working area, the
Reader
window will be opened
.
Press the
Delete button
. The
Reader
window will be closed; the
chosen reader will be deleted.
4.2.4
Internal responses
To set internal responses of the controller:
1. Click consistently
Configuration
Edit
Internal responses
in the Web-interface
menu.
The page with working area will be opened:
2. To add the new response, click the
Add
button, to change the settings of internal response
or delete it, click the title bar in the page working area. The
Internal response
window will
be opened: