settings). To operate the lock-chamber passageway control sensors are activated: PASS A for
direction of the passage 1 through OD1, PASS B for direction of the passage 2 through OD1
and the door sensor (for both directions through OD2).
Figure 20. Layout of the turnstile-and-lock lock-chamber
4. Two-turnstile lock-chamber is a zone between two turnstiles standing one behind the other in
the passage direction. Each turnstile is operated by two internal and external readers (in
regard to the lock-chamber). Reader can be replaced or duplicated by the RC button (see
below the lock-chamber OD settings). To operate the lock-chamber passageway control
sensors are activated: PASS A and PASS B of turnstile 1 for direction of the passages 1 and 2
through OD1, PASS A and PASS B of turnstile 2 for direction of the passages 1 and 2 through
OD2.
Figure 21. Layout of the two-turnstile lock-chamber
The parameters for lock-chamber ODs set in the Web-interface:
1. Access algorithm:
•
soft – leaving the lock-chamber in both directions,
•
hard – leaving the lock-chamber only in a pass-through direction.
2. Access mode:
•
by a reader,
•
by RC,
•
by a reader and RC.
3. Position (in regard to the lock-chamber placement (zone)):
•
outdoors,
•
indoors.
4. The maximum time spent in the lock-chamber – when the time is finished, the controller will
generate the event about exceeding the allotted time of staying in the lock-chamber zone.