3028
Turbo
Statistical Multiplexer
2-64
154001UA
Statistics Reset
Statistics Reset
Statistics Reset
Statistics Reset
Statistics Reset
The
STATISTICS RESET
command resets all link and channel current and
peak histories.
Front Panel Access
From the
COMMAND MODE
display:
PRESS:
NEXT or LAST
until
STATISTICS RESET
displays on the second line
PRESS:
SELECT
The multiplexer resets the statistics and returns the
COMMAND MODE
display.
Terminal Access
To access
STATISTICS RESET
from the Main Menu:
TYPE:
13
PRESS:
RETURN
The multiplexer resets the statistics and returns to the Main Menu.
The
CHANNEL VALIDATE
command initiates a test of the data path end-to-
end for the selected channel. A test word is sent to the remote end of a connec-
tion and looped back. If the initiating channel receives the looped back test
word, the test is passed. If the test word is not received back at the initiating
channel within five seconds, the test is failed.
Front Panel Access
From the
COMMAND MODE
display:
PRESS:
NEXT or LAST
until
CHNL VALIDATE
displays on the second line
PRESS:
SELECT
PRESS:
NEXT or LAST
to choose a channel number
PRESS:
SELECT
Channel Validate
Channel Validate
Channel Validate
Channel Validate
Channel Validate
Note
This channel validate test is non-interfer-
ing and can be initiated while data traffic
is active.