2. Operation of the 3028
Turbo
Multiplexer
154001UA
2-17
Front Panel Access
From the
COMMAND
mode display:
PRESS
:
NEXT or LAST
until
CHNL PARAMETERS
displays on the second line
PRESS
:
SELECT
PRESS
:
NEXT or LAST
to choose a channel number
PRESS
:
SELECT
PRESS
:
NEXT or LAST
until
CHNL n SPEED
displays on the second line
PRESS
:
SELECT
If the message is received but is garbled, either the speed was incorrectly
determined or the parity is in error. To use the built in auto-parity function to
set the parity, enter the following immediately after the
AUTOBAUD SPEED
DETECTED
message.
TYPE:
P (capital)
PRESS:
RETURN
The multiplexer will set the parity based on the
P
and
RETURN
characters
received.
Note
All channels can be set to the 19,200 speed option as
long as the maximum aggregate input does not exceed
76,800bps. Exceeding the 76,800bps input may cause
data loss. Enabling certain channel parameters can
affect the aggregate input limit. Enabling the following
channel parameters will reduce the maximum aggre-
gate input rate supported on the multiplexer: In-Band
Reverse Flow Control, Echoplex, Supervisor Enabled,
and Flyback Buffering. This is caused by the require-
ment to examine every character of data generated by
the terminal to the multiplexer.