2. Operation of the 3028
Turbo
Multiplexer
154001UA
2-75
This display appears until an event occurs. REV nnn.nn indicates the PROM
level on the multiplexer board. When you first enter MONITOR MODE (after
the PROM level display), events that have been stored in the queue display in
the order they occurred.
Logoff
Logoff
Logoff
Logoff
Logoff
The
LOGOFF
parameter ends the
COMMAND MODE
function and allows
supervisory access to other users.
To access
LOGOFF
from the Main Menu:
TYPE:
23
PRESS:
RETURN
The terminal displays:
2 0 3 1 2 -4 9
SUPERVISORY SIGNOFF AT 10:10:00
RESETTING THE
RESETTING THE
RESETTING THE
RESETTING THE
RESETTING THE
MUL
MUL
MUL
MUL
MULTIPLEXER
TIPLEXER
TIPLEXER
TIPLEXER
TIPLEXER
Coldstart
To reset the multiplexer:
1. Ensure that the front panel is in MONITOR mode.
2. Press & Hold the SELECT push button while pressing the NEXT push
button.
The system is reset and the front panel displays:
2 0 3 1 2 -5 1
SYSTEM READY
00:00:00
Warmstart
To reset the multiplexer without returning to the factory-set defaults, remove
power to the unit. Restore power to the unit. The multiplexer is reset, but the
set values remain the same.
Note
When the Multiplexer is RESET all Buffers,
Channel and Link Loopbacks, and the
Supervisor Password are Cleared. The
Supervisor is also Logged off.
The Channel and Link Parameters are
Reset to the Factory Specified Defaults.