The 3028 Turbo (CTS 2031 Turbo)
Statistical Multiplexer has been designed as a
standalone unit with open ventilation; however, the 3028 Turbo (CTS 2031 Turbo)
units can also be rack-mounted in an open rack or in an enclosed cabinet, but
only
if proper ventilation is provided.
To rack-mount the 3028 Turbo (CTS 2031 Turbo)
units, you need the rack-mount kit
which is provided in the shipping container.
The air temperature in the cabinet must not exceed 45ºC and the case temperature
of the 3028 Turbo (CTS 2031 Turbo)
must not exceed 50ºC.
Since the reliability of the product depends on the temperature, the rise on the air
temperature within the cabinet compared to the air temperature outside of the
cabinet should not be more than 10ºC. For every 10ºC increase in temperature, a
decrease of approximately 50% in the MTBF will occur.