J. EIA Signal Exceptions
154001UA
J-1
J.
J.
J.
J.
J. EIA Signal Exceptions
EIA Signal Exceptions
EIA Signal Exceptions
EIA Signal Exceptions
EIA Signal Exceptions
Care must be used when configuring the following EIA signal-related parameters.
EIA Signals received from multiplexer B's DTE (Figure J-1) will be output to
multiplexer A's DTE only if EIA propagation is enabled for that channel on both
multiplexer A and B.
1. Signal Forced
2. CTS-RTS
3. Out-of-Band Flow Control
4. EIA Propagation
Table J-1 lists the priority associated with EIA parameters.
Table J-1. EIA Parameter Priorities
For example, suppose a channel is configured for CTS-RTS and CTS-/CTS+ flow
control. The CTS output signal to that channel would always be the same as the
RTS input signal, regardless of the flow control state. Another example; suppose a
channel is configured for EIA propagation and CTS-/CTS+ flow control. The CTS
output signal would match the DRSS input signal from the remote multiplexer,
except
when CTS needs to be low due to the flow control state.