2. Operation of the 3028
Turbo
Multiplexer
154001UA
2-53
Front Panel Access
From the
COMMAND MODE
display:
PRESS:
NEXT or LAST
until
CHNL STATUS
displays on the second line
PRESS:
SELECT
PRESS:
NEXT or LAST
to choose a channel number
PRESS:
SELECT
The LCD displays:
2 03 12 -8 7
CHNL STATISTICS
Where
is
BF UTIL nn% CURR
(Current Buffer Utilization)
BF UTIL nn% PEAK
(Peak Buffer Utilization)
EXC nnnn FC nnnn
(Channel Exceptions - Flow Control)
RV FC nnnn
(Reverse Flow Control)
PRESS:
NEXT or LAST
to scroll through statistics
PRESS:
MON/CLR
to exit
To update the channel statistics display:
PRESS:
SELECT
To display the channel status in real-time (continuous update):
PRESS & HOLD:
SELECT
PRESS:
MON/CLR
Release the keys. The display is continuously updated each second, providing
the ability to dynamically track the displayed channel statistics parameter.
PRESS:
MON/CLR
to exit
Note
nn is the utilization percentage. nnn is the
number or occurrences.