3-14
Chapter 3 Troubleshooting
003-795 AMS Limit Error
BSD on : CH6.12B
[Detection Conditions]
AMS magnification limit error (The magnification
ratio becomes out of limit after the document auto
detection when the AMS is specified).
[Actions]
No actions required.
003-940 Vertical/horizontal number mismatch (when
Poster is specified)
BSD on : CH6.12B
[Detection Conditions]
Vertical/horizontal number
mismatch (when Poster is specified)
[Actions]
Perform the operation again.
003-941 Insufficient page memory
BSD on : CH6.12B
[Detection Conditions]
Insufficient page memory
[Actions]
Perform the operation again.
003-942 Paper size error
BSD on : CH6.12B
[Detection Conditions]
Document size error
[Actions]
Perform the operation again.
003-943 Shortage of card value
BSD on : CH3.6B
[Detection Conditions]
Shortage of card value
[Actions]
Perform the operation again.
003-944 Incorrect number of image repeats
BSD on : CH6.12B
[Detection Conditions]
Incorrect number of image
repeats
[Actions]
Perform the operation again.
003-945 Vertical/horizontal number mismatch (When
other than Poster is selected and the
switching of rotations is displayed.)
BSD on : CH6.12B
[Detection Conditions]
Vertical/horizontal number mismatch (When other
than Poster is selected and the switching of rotations is
displayed.)
[Actions]
Perform the operation again.
003-946 TRAY 1 NOT IN POSITION
Description
TRAY 1 is not set in place.
BSD on : CH7.1 CH7.10A
Procedure
Push Tray 1 in the M/C.
Is +3.38 VDC or higher measured between the I/F PWB J536-
B9 (+) and GND (-)?
Y
N
Check the wire between the I/F PWB and the MCU PWB.
If no problems are found, replace the MCU PWB
(PL13.1).
With the Tray 1 pulled out, check the settings of the paper size.
Are the settings correct?
Y
N
Set the paper size again.
Is +3.38 VDC or higher measured between the TRAY 1 SIZE
SENSOR J115-2 (+) and GND (-)?
Y
N
Check the wire between the TRAY 1 SIZE SENSOR J115-
2 and the I/F PWB J536-B9 for an open circuit and poor
contact.
Is +3.3 VDC measured between the TRAY 1 SIZE SENSOR
J115-1 (+) and GND (-)?
Y
N
Check the +3.3 VDC circuit to the TRAY 1 SIZE
SENSOR J115-1 by referring to Chapter 4 Wiring
Data.(WN4.3.3 +3.3 VDC)
Is +3.3 VDC measured between the TRAY 1 SIZE SENSOR
J115-1 (+) and J115-3 (-)?
Y
N
Check the DC COM circuit to the TRAY 1 SIZE SENSOR
J115-3 by referring to Chapter 4 Wiring Data.(WN4.3.3
+3.3 VDC)
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......