3-70
Chapter 3 Troubleshooting
Y
N
Check the +24 VDC circuit to the AC
DRIVE PWB J590-1 by referring to
Chapter 4 Wiring Data.
(WN4.3.13 +24 VDC-1)
(WN4.3.14 +24 VDC-2)
(WN4.3.15 +24 VDC-3)
(WN4.3.16 +24 VDC-4)
Is 0 VDC measured between the AC DRIVE
PWB J590-2 (+) and GND (-)?
Y
N
Is 0 VDC measured between the MCU
PWB J404-8 (+) and GND (-)?
Y
N
Check the wire between the AC
DRIVE PWB J590-2 and the MCU
PWB J404-8 for an open circuit and
poor contact. If no problems are
found, replace the MCU PWB.
(PL13.1)
Check the wire between the AC DRIVE
PWB J590-2 and the MCU PWB J404-8 for
an open circuit and poor contact.
Replace the AC DRIVE PWB. (PL9.2)
Check the wires between the AC DRIVE PWB FS47
and the FUSER ASSY J600-3 and between the AC
DRIVE PWB FS48 and the FUSER ASSY J600-12
for an open circuit and poor contact.
Check the wire between the AC DRIVE PWB J590-3 and
the MCU PWB J404-7 for an open circuit and poor
contact.
Check the wire for a short circuit to the frame. If no problems
are found, replace the MCU PWB. (PL13.1)
010-356 SUB HEATER ON TIME FAILURE
Description
The SUB HEATER continued to light up for more
than the specified time.
BSD on : CH10.1 CH10.8
Procedure
Turn Off the power, remove the FUSER ASSY, and allow it to
cool down.
Measure the resistance between the FUSER ASSY connectors
P600-7 (+) and P600-9 (-).
Is the resistance between 30 and 190 k Ohm?
Y
N
Check the REAR THERMISTOR in the FUSER ASSY for
an open circuit and poor contact. If no problems are found,
replace the FUSER ASSY. (PL7.1)
Measure the resistance between the FUSER ASSY P600-3 (+)
and P600-12 (-).
Is the resistance 20 Ohm or less?
Y
N
Check the wire in the FUSER ASSY for an open circuit
and poor contact, and the THERMOSTAT for an open
circuit. If no problems are found, replace the FUSER
ASSY. (PL7.1)
Reinstall the FUSER ASSY, turn On the power, and run
DC140
[010-101].
Is the monitor value between 900 and 1000?
Y
N
Turn Off the power and check the wire between the MCU
PWB J404-14 and the REAR THERMISTOR J212-1 for
an open circuit and poor contact.
Is the open circuit or poor contact found?
Y
N
Check the wire between the MCU PWB J404-13 and
the REAR THERMISTOR J212-2 for an open circuit
and poor contact.
Is the open circuit or poor contact found?
Y
N
Replace the MCU PWB. (PL13.1)
Repair the open circuit or poor contact.
Repair the open circuit or poor contact.
Measure the voltage between the MCU PWB J404-7 (+) and
GND (-).
Is 0 VDC measured before a failure occurs?
Y
N
Measure the voltage between the AC DRIVE PWB J590-3
(+) and GND (-).
Is 0 VDC measured before a failure occurs?
Y
N
Is 0 VDC measured between the AC DRIVE PWB
J590-4 (+) and GND (-)?
Y
N
Check the DC COM circuit to the AC DRIVE
PWB J590-4 by referring to Chapter 4 Wiring
Data.
(WN4.3.9 +5 VRET-1)
(WN4.3.10 +5 VRET-2)
(WN4.3.11 +5 VRET-3)
(WN4.3.12 +5 VRET-4)
Is 100 VAC measured between the AC DRIVE PWB
FS48 (+) and FS47 (-)?
Y
N
Is 100VAC measured between the AC DRIVE
PWB FS39 (+) and FS40 (-)?
Y
N
Check the AC circuit to the AC DRIVE
PWB FS39 and FS40 by referring to Chap-
ter 4 Wiring Data. (WN4.3.1 ACH/
WN4.3.2 ACN)
Is +24 VDC measured between the AC DRIVE
PWB J590-1 (+) and GND (-)?
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......