3-262
Chapter 3 Troubleshooting
[Description]:
Failure when new Toner Cartridge is installed and the Disp Motor Drive did not
shift from new to old. 0: Normal 1: Error
115.752-787
[NVM Name]: Failure Disp Unusual [K]
[PSW Display]: Failure Disp Unusual [K]
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
Failure when new Toner Cartridge is installed and the Disp Motor Drive did not
shift from new to old. 0: Normal 1: Error
116.752-788
[NVM Name]: Minimum PV Threshold
[PSW Display]: Min PV Threshold
[Initial Value]: 3
[Setup Range]: 0~255
[Description]: Minimum PV from Near empty to empty (M/Cstop)
117.752-804
[NVM Name]: Cumulative Disp Time for deterioration correction [Y]
[PSW Display]: DispTime Totalizing value for Aged Correction [Y]
[Initial Value]: 0
[Setup Range]: 0~4294967295
[Description]:
Cumulative Disp Time for deterioration correction amount of the ATC Control
Nominal Value.
Cleaned to 0 at replacement of Developer.
118.752-805
[NVM Name]: Cumulative Disp Time for deterioration correction [M]
[PSW Display]: DispTime Totalizing value for Aged Correction [M]
[Initial Value]: 0
[Setup Range]: 0~4294967295
[Description]:
Cumulative Disp Time for deterioration correction amount of the ATC Control
Nominal Value.
Cleaned to 0 at replacement of Developer.
119.752-806
[NVM Name]: Cumulative Disp Time for deterioration correction [C]
[PSW Display]: DispTime Totalizing value for Aged Correction [C]
[Initial Value]: 0
[Setup Range]: 0~4294967295
[Description]:
Cumulative Disp Time for deterioration correction amount of the ATC Control
Nominal Value.
Cleaned to 0 at replacement of Developer.
120.752-807
[NVM Name]: Cumulative Disp Time for deterioration correction [K]
[PSW Display]: DispTime Totalizing value for Aged Correction [K]
[Initial Value]: 0
[Setup Range]: 0~4294967295
[Description]:
Cumulative Disp Time for deterioration correction amount of the ATC Control
Nominal Value.
Cleaned to 0 at replacement of Developer.
121.752-814
[NVM Name]: Pre Near Factor
[PSW Display]: Pre Near EMP Factor
[Initial Value]: 80
[Setup Range]: 0~255
[Description]: Factor correcting [Near Detection Nominal Value] after Pre Near is
displayed.
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......