3-220
Chapter 3 Troubleshooting
97. 715-815
[NVM Name]: Lamp Failure
[PSW Display]: Lamp Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
98. 715-816
[NVM Name]: CRG Over Run Failure (Scan End)
[NVM Name]: CRG Over Run Failure Count Overall Total (Scan End)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
99. 715-817
[NVM Name]: CRG Over Run Failure (Scan End)
[NVM Name]: CRG Over Run Failure Count Since Reset (Scan End)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
100.715-818
[NVM Name]: CRG Over Run Failure (Home End)
[NVM Name]: CRG Over Run Failure Count Overall Total (Home End)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
101.715-819
[NVM Name]: CRG Over Run Failure (Home End)
[NVM Name]: CRG Over Run Failure Count Since Reset (Home End)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
102.715-820
[NVM Name]: Scan Initialize Motor Driver Failure
[PSW Display]: CRG INIT Motor Driver Failure Count Overall Total
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
103.715-821
[NVM Name]: Scan Initialize Motor Driver Failure
[PSW Display]: CRG INIT Motor Driver Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
104.715-822
[NVM Name]: Platen AGC CH1 Failure
[PSW Display]: Platen AGC Channel 1 Failure Count Overall Total
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
105.715-823
[NVM Name]: Platen AGC CH1 Failure
[PSW Display]: Platen AGC Channel 1 Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
106.715-824
[NVM Name]: Platen AGC CH2 Failure
[PSW Display]: Platen AGC Channel 2 Failure Count Overall Total
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
107.715-825
[NVM Name]: Platen AGC CH2 Failure
[PSW Display]: Platen AGC Channel 2 Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
108.715-826
[NVM Name]: Platen AGC CH3 Failure
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......