3-25
Chapter 3 Troubleshooting
Y
N
Check the wire between the I/F PWB J533 and
the IBT EDGE SENSOR J119 for an open
circuit and poor contact. If no problems are
found, replace the IBT EDGE SENSOR
(PL5.4). If the problem persists, replace the
MCU PWB.(PL13.1)
Check the wire between the I/F PWB J533-A11 and
the IBT EDGE SENSOR J119-2 for an open circuit or
poor contact.
Replace the IBT EDGE SENSOR.(PL5.4)
Is +24 VDC measured between the I/F PWB J530-A9 (+) and
GND (-)?
Y
N
Check the +24 VDC circuit to the I/F PWB J530-A9 by
referring to Chapter 4 Wiring Data.
(WN4.3.13 +24 VDC-1) (WN4.3.14 +24 VDC-2)
(WN4.3.15 +24 VDC-3) (WN4.3.16 +24 VDC-4)
Remove the IBT ASSY and run
DC330
[004-001].
Is the IBT STEERING MOTOR rotating?
Y
N
Check the wire between the I/F PWB J550 and the IBT
STEERING MOTOR J207 for an open circuit and poor
contact.
Is an open circuit or poor contact found?
Y
N
Replace the MCU PWB (PL13.1). If the problem
persists, replace the I/F PWB (PL9.1) and the IBT
STEERING MOTOR.(PL1.3)
Repair the open circuit or poor contact.
Check the installation status of the IBT BELT. If no problems
are found, replace the MCU PWB.(PL13.1)
004-641 BELT EDGE LEARN FAILURE
Description
IBT BELT EDGE adjustment failure
BSD on : CH9.19 CH9.31A
Procedure
Is the Actuator of the Edge Sensor touching the BELT?
Y
N
Check the installation status of the Actuator.
Turn On the power.
Run
DC330
[004-014].
Is +3 VDC to +1 VDC measured between the I/F PWB J533-
A11 (+) and GND (-)?
Y
N
Is +5 VDC measured between the I/F PWB J533-A9 (+)
and J533-A10 (-)?
Y
N
If the voltage between the I/F PWB J533-A9 (+) and
the J533-A10 (-) is less than +5 VDC after closing the
FRONT door, replace the MCU MF PWB.(PL13.1)
Is +5 VDC measured between the I/F PWB J533-A11 (+)
and GND (-)?
Y
N
Is 0 VDC measured between the I/F PWB J533-A11
(+) and GND (-)?
Y
N
Check the wire between the I/F PWB J533 and
the IBT EDGE SENSOR J119 for an open
circuit and poor contact. If no problems are
found, replace the IBT EDGE SENSOR
(PL5.4). If the problem persists, replace the
MCU PWB. (PL13.1)
Check the wire between the I/F PWB J533-A11 and
the IBT EDGE SENSOR J119-2 for an open circuit or
poor contact.
Replace the IBT EDGE SENSOR.(PL5.4)
Is +24 VDC measured between the I/F PWB J530-A9 (+) and
GND (-)?
Y
N
Check the +24 VDC circuit to the I/F PWB J530-A9 by
referring to Chapter 4 Wiring Data.
(WN4.3.13 +24 VDC-1) (WN4.3.14 +24 VDC-2)
(WN4.3.15 +24 VDC-3) (WN4.3.16 +24 VDC-4)
Remove the IBT ASSY and run
DC330
[004-001].
Is the IBT STEERING MOTOR rotating?
Y
N
Check the wire between the I/F PWB J550 and the IBT
STEERING MOTOR J207 for an open circuit and poor
contact.
Is an open circuit or poor contact found?
Y
N
Replace the MCU PWB (PL13.1). If the problem
persists, replace the I/F PWB (PL9.1) and the IBT
STEERING MOTOR.(PL1.3)
Repair the open circuit or poor contact.
Check the installation status of the IBT BELT. If no problems
are found, replace the MCU PWB.(PL13.1)
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......