![Panasonic Workio DP-C401 Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/panasonic/workio-dp-c401/workio-dp-c401_service-handbook_257331081.webp)
3-7
Chapter 3 Troubleshooting
003-322 IISS-ESS Communication Failure 3
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Incorrect Packet No.)
ACK cannot be received after resending it twice. (The
Packet No. of the message Packet that has been sent is
not correct.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Connection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
003-323 IISS-ESS Communication Failure 4
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Incorrect message length)
ACK cannot be received after resending it twice. (The
message length of the message packet that has been
sent is not correct.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Connection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
003-324 IISS-ESS Communication Failure 5
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Check Code Error)
ACK cannot be received after resending it twice. (The
Check Code of the message packet that has been sent
is not correct.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Connection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
003-325 IISS-ESS Communication Failure 6
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Parity Error)
ACK cannot be received after resending it twice. (A
parity error is found in the hardware at the IISS side.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Con
nection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
003-326 IISS-ESS Communication Failure 7
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Flaming Error)
ACK cannot be received after resending it twice. (A
flaming error is found in the hardware at the IISS
side.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Connection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
003-327 IISS-ESS Communication Failure 8
BSD on : CH12.2A
[Detection Conditions]
SCOPE-FD sending error that will be detected by the
Controller (Overrun Error)
ACK cannot be received after resending it twice. (An
overrun error is found in the hardware at the IISS
side.)
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Check the connection of the IIT/IPS (PL16.3)
Connection Harness.
(2) Software matching error. Perform re-installation of
the software.
(3) If the problem persists after the above actions,
replace the IIT/IPS (PL16.3).
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......