3-259
Chapter 3 Troubleshooting
81. 752-360
[NVM Name]: Timer Dispense time [K]
[PSW Display]: Timer Disp time [K]
[Initial Value]: 5
[Setup Range]: 0~250
[Description]: Timer Disp Setup Time
82. 752-369
[NVM Name]: SW Potential Control On/Off
[PSW Display]: SW Potential Control ON/OFF
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
0: Controls LD Light Quantity (See [Ideal Light Quantity])
1: Fixed LD Light Quantity (See [LD Light Quantity when Potential Control is
Off])
83. 752-371
[NVM Name]: LD Light Quantity when Potential Control is Off [Y]
[PSW Display]: LD Light q'ty when Potential Control is OFF [Y]
[Initial Value]: 300
[Setup Range]: 0~1023
[Description]: LD Light Quantity Value when Potential Control is Off.
84. 752-372
[NVM Name]: LD Light Quantity when Potential Control is Off [M]
[PSW Display]: LD Light q'ty when Potential Control is OFF [M]
[Initial Value]: 300
[Setup Range]: 0~1023
[Description]: LD Light Quantity Value when Potential Control is Off.
85. 752-373
[NVM Name]: LD Light Quantity when Potential Control is Off [C]
[PSW Display]: LD Light q'ty when Potential Control is OFF [C]
[Initial Value]: 300
[Setup Range]: 0~1023
[Description]: LD Light Quantity Value when Potential Control is Off.
86. 752-374
[NVM Name]: LD Light Quantity when Potential Control is Off [K]
[PSW Display]: LD Light q'ty when Potential Control is OFF [K]
[Initial Value]: 300
[Setup Range]: 0~1023
[Description]: LD Light Quantity Value when Potential Control is Off.
87. 752-375
[NVM Name]: Ideal LD Light Quantity [Y]
[PSW Display]: Ideal LD light qty [Y]
[Initial Value]: 450
[Setup Range]: 0~1023
[Description]: LD Light Quantity Ideal Value Calculated from Delta LD Light
Quantity.
88. 752-376
[NVM Name]: Ideal LD Light Quantity [M]
[PSW Display]: Ideal LD light qty [M]
[Initial Value]: 450
[Setup Range]: 0~1023
[Description]: LD Light Quantity Ideal Value Calculated from Delta LD Light
Quantity.
89. 752-377
[NVM Name]: Ideal LD Light Quantity [C]
[PSW Display]: Ideal LD light qty [C]
[Initial Value]: 450
[Setup Range]: 0~1023
[Description]: LD Light Quantity Ideal Value Calculated from Delta LD Light
Quantity.
90. 752-378
[NVM Name]: Ideal LD Light Quantity [K]
[PSW Display]: Ideal LD light qty [K]
[Initial Value]: 400
[Setup Range]: 0~1023
[Description]: LD Light Quantity Ideal Value Calculated from Delta LD Light
Quantity.
91. 752-394
[NVM Name]: JobS Delta LD Limit
[PSW Display]: Change in Lim_d_LD Light qty on Jobstart
[Initial Value]: 40
[Setup Range]: 0~1023
[Description]: Limit of Delta LD Light Quantity Feedback at Job Start.
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......