Chapter 3 Troubleshooting
116-336 Redirector HDD Failure
[Detection Conditions]
<Redirector Failure>
HD failure to be detected by Redirector
[Actions]
Take actions by following the procedure below.
(1) Set up the HDD.
(2) Replace the HDD (PL13.1).
(3) Replace the ESS Board (PL13.1).
116-337 Template HD Write Error
[Detection Conditions]
<Write error in obtaining JT>
An error has occurred when the Job Template was
stored in the local HD.
[Actions]
Take actions by following the procedure below.
(1) Set up the HDD.
(2) Replace the HDD (PL13.1).
(3) Replace the ESS Board (PL13.1).
116-340 Short of Memory
[Detection Conditions]
When the system detected that the
memory was insufficient.
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Add memory
(2) Pull out PostScript option.
116-341 ROM DIMMs Mismatch
[Detection Conditions]
[Detection Conditions] several invalid ROM DIMM
versions that are installed The combination of the
installed ROM DIMMs is invalid for use at the same
time. When installing multiple ROM DIMMs, it is
necessary to match the major version with the minor
version.
[Actions]
Turn the power On/Off.
116-342 JT Monitor Failure
[Detection Conditions]
<JT Monitor Failure>
Fatal errors to be detected by the JT monitor
[Actions]
Take actions by following the procedure below.
(1) Turn Off and On the power.
(2) Replace the ESS Board (PL13.1).
116-344 MFIO Failure
[Detection Conditions]
<MFIO Failure>
Fatal errors to be detected by MFIO
[Actions]
Take actions by following the procedure below.
(1) Turn Off and On the power.
(2) Replace the ESS Board (PL13.1).
116-345 (Not used)
116-346 Formatter Failure
[Detection Conditions]
Fatal errors to be detected by the Formatter were
detected.
[Actions]
(1) Turn the power Off and On.
(2) If the trouble persists, replace the ESS PWB
(PL13.1).
116-347 LocalTalk Board Failure
[Detection Conditions]
The LocalTalk board cannot be
activated successfully.
[Actions]
If there is no appropriate PWB in the DPC 2220, this
code is not supposed to occur.
116-348 Redirecter Failure
[Detection Conditions]
<Redirecter Failure>
Fatal errors to be detected by Redirecter
[Actions]
Take actions by following the procedure below.
(1) Turn Off and On the power.
(2) Replace the ESS Board (PL13.1).
116-349 SIF Failure on Calling Pflite Function
[Detection Conditions]
An error has occurred when calling the Pflite function
with SIF.
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
Replace the ESS PWB (PL13.1).
116-350 AppleTalk Soft Failure
[Detection Conditions]
Overall fatal errors of the AppleTalk
Due to an error during the software processing, the
subsequent processes cannot be performed.
[Actions]
Turn the power On/Off and perform the following if
the problem persists.
(1) Perform re-installation of the ESS software.
(2) Replace the ESS PWB (PL13.1).
116-351 EtherTalk Soft Failure
[Detection Conditions]
Fatal error related to the EtherTalk
Due to an error during the software processing, the
subsequent processes cannot be performed.
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......