3. 4. 4. 19 DC685 Regi Control Setup Cycle (Registration)
Function Sets or displays the optimal values of skew and the NVM values of other Regi control
correction systems.
• This is the cycle to set the optimal values of the skew and the NVM values of other Regi
Control correction systems, assuming that this is executed at factory shipment and at LSU
(ROS) replacement in the field. Only this cycle detects and corrects the skew and
magnification balance.
• There are four functions of the Regi Control Setup Cycle. These functions work
independently. Usually, they are performed in the order of 1-2-3. Perform Procedure 4. Skew
Rough Setup only when an error is displayed during Procedures 2 and 3. For details, refer to
Chapter 2 ADJ1.1.6 Regi Control Adjustment.
(1) Skew Fine SetUp
(2) IN/OUT SetUp
(3) Center SetUp
(4) Skew Rough SetUp
• Overview of the results detected by Regi Control Setup Cycle
Reference
Execution Time: Approx
.
2 mins 30 sec.
Procedure
1. Select "Registration" tab on the Service Mode screen.
2. Select [
DC685
] on the Registration screen.
3. The Regi Control Setup Cycle screen is displayed.
The following DC subcodes can be selected in the combo boxes for each execution type.
4. Perform the procedures in the order of DC685-1 -> 2 -> 3. Regi results are not guaranteed if
you perform the DC subcode along the way. For details, refer to Chapter 2 ADJ1.1.6 Regi
Control Adjustment.
5. Select [Close] to return to the Registration screen.
Displayed Data
Display Range
Unit
Remarks
Skew correction amount
-5.00(CCW) ~
+5.00(CW)
No. of rev-
olutions
Target Colors = Y, M, C, K
No. of revolutions=skew
amount (micro-m)/100
Skew amount
-500~+500
micron
Detection value of the Regi
Control Temperature Sensor
-20~60
Degrees
Celsius
Latest data at execution of
this cycle
Number of Blocks detected
(IN/OUT)
0~24
BLOCK
• Be sure that the DC956 Belt Edge Learn mode is completed successfully before
execution of DC685.
• If the Skew Rough SetUp is not completed successfully, there is a fatal error for
Regi Control execution. Cause must be identified by DC681 and DC683.
Sub DC code name
Name
Check Items in the
Execution Result Values
DC685-1
Skew Fine SetUp
IN/OUT only
DC685-2
IN/OUT SetUp
IN/OUT only
DC685-3
Centre SetUp
Centre only
DC685-4
Skew Rough SetUp
IN/OUT only
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......