![Panasonic Workio DP-C401 Скачать руководство пользователя страница 299](http://html.mh-extra.com/html/panasonic/workio-dp-c401/workio-dp-c401_service-handbook_257331299.webp)
3-225
Chapter 3 Troubleshooting
3. 5. 9 DC131 740-xxx IOT Manager NVM List
1. 740-024
[NVM Name]: For checking Regi Control at Power On.
[PSW Display]: RegiCon Request Flag
[Initial Value]: 0
[Setup Range]: 0~255
[Description]: 0: Performed, 1: Not performed
2. 740-025
[NVM Name]: For checking Edge Check at Power On.
[PSW Display]: Edge Check Request Flag
[Initial Value]: 0
[Setup Range]: 0~255
[Description]: 0: Performed, 1: Not performed
3. 740-026
[NVM Name]: For checking Process Control at Power On.
[PSW Display]: ProCon Request Flag
[Initial Value]: 0
[Setup Range]: 0~255
[Description]: 0: Performed, 1: Not performed