3-276
Chapter 3 Troubleshooting
[Initial Value]: 237
[Setup Range]: 0~474
[Description]:
Adjusts the Slow Scan direction write start position by the No. of LS Signal
Counts from the LSU (ROS)/Image/Patch Start Signal. (4 Colors/Correction
Resolution Ability: 1 Pixel unit)
20. 760-025
[NVM Name]: YSO-C
[PSW Display]: C-YSO
[Initial Value]: 237
[Setup Range]: 0~474
[Description]:
Adjusts the Slow Scan direction write start position by the No. of LS Signal
Counts from the LSU (ROS)/Image/Patch Start Signal. (4 Colors/Correction
Resolution Ability: 1 Pixel unit)
21. 760-026
[NVM Name]: YSO-K
[PSW Display]: K-YSO
[Initial Value]: 237
[Setup Range]: 0~474
[Description]:
Adjusts the Slow Scan direction write start position by the No. of LS Signal
Counts from the LSU (ROS)/Image/Patch Start Signal. (4 Colors/Correction
Resolution Ability: 1 Pixel unit)
22. 760-027
[NVM Name]: Regi Con/Circumference Length Correction Implementation SW
[PSW Display]: Regi Con/Circum. Length Correction implement SW
[Initial Value]: 3
[Setup Range]: 0~3
[Description]:
For check during servicing etc.
0: Does not perform Regi Control nor Circumference Length Correction
1: Performs Regi Control, does not perform Circumference Length Correction
2:
Does not perform Regi Control, performs Circumference Length Correction
3: Performs Regi Control and Circumference Length Correction
23. 760-028
[NVM Name]: RC Start Temp
[PSW Display]: RC Start Temp
[Initial Value]: 40
[Setup Range]: 10~250
[Description]:
Threshold of (Normal) Regi Control Implementation Temperature difference.
Value on the left is 10 times of the Temperature. (0.1 Degree Celsius interval)
24. 760-029
[NVM Name]: OLRC Implementation SW
[PSW Display]: OLRC implementation SW
[Initial Value]: 1
[Setup Range]: 0~1
[Description]:
0: Does not perform OLRegi Control
1: Performs OLRegi Control
25. 760-030
[NVM Name]: OLRC Start Temp-Y
[PSW Display]: Y-OLRC Start Temp
[Initial Value]: 30
[Setup Range]: 10~100
[Description]:
Threshold of Yellow Open Loop Regi Control Implementation Temperature difference.
Value on the left is 10 times of the Temperature. (0.1 Degree Celsius interval)
26. 760-031
[NVM Name]: OLRC Start Temp-M
[PSW Display]: M-OLRC Start Temp
[Initial Value]: 30
[Setup Range]: 10~100
[Description]:
Threshold of Magenta Open Loop Regi Control Implementation Temperature difference.
Value on the left is 10 times of the Temperature. (0.1 Degree Celsius interval)
27. 760-032
[NVM Name]: OLRC Start Temp-K
[PSW Display]: K-OLRC Start Temp
[Initial Value]: 30
[Setup Range]: 10~100
[Description]:
Threshold of Black Open Loop Regi Control Implementation Temperature difference.
Value on the left is 10 times of the Temperature. (0.1 Degree Celsius interval)
Содержание Workio DP-C401
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......