162
Chapter 5
Troubleshooting
This section describes how to solve the problems.
If your
S-LINK V
system does not operate properly, refer to this section.
Flowchart for taking corrective action for detected error
You can check the detected error using the LED indicators or the address display of the controller.
After checking the detected error, solve the problem as shown below:
: Judgement
: Corrective action
: Transition to another flow
: Starting of flow
: Ellimination of cause of error
<For S-LINK V controller>
Occurrence of error
Check the system configuration.
Check the details of the error.
Check that the power is supplied.
Also check the +24V to 0V line for
short-circuit.
An error is detected, but the cause
of the error is already eliminated.
Check the details of the error, and take mea-
sures against the error.
If no measures are taken, the same error may
occur again.
The error indicator will stop blinking.
The error number shown on the address display
will disappear.
Dose not perform
rotational indication.
Check the error indicator.
Check that the CONFIG
mode is selected.
Refer to page 166.
Refer to page 165.
Refer to page 164.
Off
On
Check the address display.
On / Blinking
On
No
Off
Blinking
Yes
Check the error indicator.
All are off.
One of them is on or blinking.
Check the transmissoin
indicator and the address
display of the controller.
Off
Blinking
Check the transmission indicator.
Replace the controller.
Switch the mode to RUN or
CHECK mode.
Press ENTER, , and buttons
at the same time
Replace the controller.
Содержание S-LINK V
Страница 2: ...2 ...
Страница 5: ...5 Before Using This System ...
Страница 12: ...12 Before Using This System MEMO ...
Страница 13: ...13 Chapter 1 Designing System ...
Страница 35: ...35 Chapter 2 Wiring ...
Страница 60: ...60 Chapter 2 MEMO ...
Страница 61: ...61 Chapter 3 Starting System ...
Страница 71: ...71 Chapter 4 Specifications ...
Страница 161: ...161 Chapter 5 Troubleshooting ...
Страница 169: ...169 Appendix ...
Страница 180: ...180 Appendix MEMO ...