159
Chapter 4
List of Models
List of connectors
Designation
Model No.
Description
Hook-up connector
SL-J1A
This connector enables a ‘T’ - branch of the exclusive 4-core flat cable.
For 0.5mm
2
to 0.5mm
2
(Gray)
Hook-up connector for cable
extension
SL-J3A
Used for extension of the exclusive 4-core flat cable.
For 0.5mm
2
to 0.5mm
2
(Black)
Hook-up connector for cable
end
SL-JK
If the snap male connector (
SL-CP
□) is used together, this hook-up connector
(
SL-JK
) enables connection of the I/O unit to the end of the exclusive 4-core flat
cable (0.5mm
2
). (Light blue)
Hook-up connector for 'T' -
branch
SL-JK1
If the snap male connector (
SL-CP
□) is used together, this hook-up connector
(
SL-JK1
) enables connection of the I/O unit to any point of the exclusive 4-core flat
cable (0.5mm
2
). (Blue)
Snap male connector
SL-CP1
For 0.08 to 0.2mm
2
Lead wire diameter: ø0.7 to ø1.2mm
(White)
Used for connection of the I/O device to the
SL-VT□J
/
SL-VTP□J
connector I/O unit or con-
nection of the
S-LINK V
I/O unit to the
SL-JK
/
SL-JK1
hook-up connector.
SL-CP2
For 0.3mm
2
Lead wire diameter: ø1.1 to ø1.6mm
(Black)
SL-CP3
For 0.5mm
2
Lead wire diameter: ø1.7 to ø2.5mm
(Bluish green)
Snap female connector
SL-CJ1
For 0.08 to 0.2mm
2
Lead wire diameter: ø0.7 to ø1.2mm
(White)
Used for connection to the
SL-CP□
snap male
connector.
SL-CJ2
For 0.3mm
2
Lead wire diameter: ø1.1 to ø1.6mm
(Black)
We can provide connectors in units of 10-connector sets.
If you need connectors, please let us know how many sets you need (1 set: 10 pcs.)
NOTE
Handy monitor
Designation
Model No.
Description
Handy monitor
SL-VHM1
This monitor can be connected to any point of the signal transmission line, and en-
ables monitoring of the I/O conditions in units of 16 points.
In addition, this monitor is incorporated with the
S-LINK V
controller functions. For
this reason, even in the middle of installation work, this monitor can carry out I/O
check for a divided conveyor, or the like, without activating the
S-LINK V
controller.
Address setting remote controller
Designation
Model No.
Description
Address setting remote
controller
SL-VAR1
This remote controller is designed specifically to select the
SL-VPK0□
address and
lamp color and to change its address offset.
It can also send and receive all settings at once using infrared communications.
Содержание S-LINK V
Страница 2: ...2 ...
Страница 5: ...5 Before Using This System ...
Страница 12: ...12 Before Using This System MEMO ...
Страница 13: ...13 Chapter 1 Designing System ...
Страница 35: ...35 Chapter 2 Wiring ...
Страница 60: ...60 Chapter 2 MEMO ...
Страница 61: ...61 Chapter 3 Starting System ...
Страница 71: ...71 Chapter 4 Specifications ...
Страница 161: ...161 Chapter 5 Troubleshooting ...
Страница 169: ...169 Appendix ...
Страница 180: ...180 Appendix MEMO ...