89
Chapter 4
Specifications
●
Specifications
Type
For PCI bus
For VME bus
Model No.
SL-VPCI
SL-VVMES2
Supply voltage (Note 1)
[
S-LINK V
system side] 24V DC
+10
− 5
%
[Bus side] 5V DC±5%
Current consumption
[24V DC] 85mA or less (Note 2)
[24V DC] 88mA or less (Note 2)
[24V DC (power supply to load driving
S-LINK V
I/O unit)]
Maximum current supplied: 7A (For one port for
SL-VVMES2
) (Note 3)
[5V DC] 315mA or less
[5V DC] 880mA or less
Connecting method
‘T’-branch connection or multi-drop connection
Number of I/O control
points
Maximum 512 points (Note 4) (using DIP switches, in increments / decrements of 32 points / I/O setting using the
program in increments / decrements of 16 points is also possible).
Indicators
Transmission
Green LED (blinks during transmission)
BUSY
Orange LED (Lights up at starting and during system setting operation, turns off during transmission)
Error
Red LED (Lights up when an error occurs, blinks when the cause of the error is eliminated, turns off when normal
operation is performed.)
Compatible bus
PCI bus (Note 5)
VME bus
Environmental resistance
Ambient tempera-
ture (Note 6)
0 to +55ºC (No dew condensation), Storage: -20 to +70ºC
Ambient humidity
(Note 6)
20 to 85% RH, Storage: 20 to 85% RH
Noise immunity
(Note 6)
Power line: 500Vp, 10ms cycle, 1μs pulse width
Common: 1,000Vp, 10ms cycle, 1μs pulse width (with noise simulator)
Voltage withstandability
(Note 6)
1,000V AC for one min. between external terminal and ground
Insulation resistance
(Note 6)
20MΩ, or more, with 500V DC megger between external terminal and ground
Vibration resistance
(Note 6)
10 to 150Hz frequency, 0.75mm amplitude or maximum acceleration 49m/s² in X, Y and Z directions for two
hours each
Shock resistance
(Note 6)
98m/s
2
acceleration (approx. 10G) in X, Y and Z directions for three times each
Grounding method
Bracket: Floating,
S-LINK V
system side: C-connection
Interruption function
(Note 7)
Interruption will be performed if an error or input
change occurs
(enabling / disabling this function is possible).
Setting of ‘Not used,’ IRQ1 to IRQ7, and status / ID is
possible.
[Status / ID transfer capability: D08 (O)]
Interruption will be performed if an error or input
change occurs (enabling / disabling this function is
possible).
Notes: 1) 24V DC and 5V DC are insulated from each other. For the
SL-VVMES2
, the
S-LINK V
transmission ports are also insulated.
2) The current consumption value is the total of the maximum current value (D-G line only) supplied to the
S-LINK V
I/O units and the
current consumption value of the
S-LINK V
control board.
3) This product is not equipped with any short-circuit protective function.
For this reason, select a power supply unit having short-circuit protective function (fuse, etc.).
4) For the
SL-VVMES2
, the maximum number of I/O control points is 1,024 points (512 points, maximum ´ 2 ports).
5) If you need a driver, download the driver from “
our Internet homepage: https://panasonic.net/id/pidsx/global
.”
[We can provide drivers for DOS, Windows 95/98/Me(32bit), Windows NT 4.0(32bit), Windows2000/XP/7(32bit) and Windows
10(64bit).] If you cannot access to our Internet homepage, please contact the store where you bought our product or our sales office.
6) This value is for the control board single body. If the control board is installed on the computer, compare the specifications of the con
-
trol board with those of the computer, and observe the specifications showing the lower value.
7) The interruption function can be enabled or disabled for each point. However, the interruption condition (ON→OFF / OFF→ON) is ap
-
plied to all the input points, and application to each point is not possible.
Содержание S-LINK V
Страница 2: ...2 ...
Страница 5: ...5 Before Using This System ...
Страница 12: ...12 Before Using This System MEMO ...
Страница 13: ...13 Chapter 1 Designing System ...
Страница 35: ...35 Chapter 2 Wiring ...
Страница 60: ...60 Chapter 2 MEMO ...
Страница 61: ...61 Chapter 3 Starting System ...
Страница 71: ...71 Chapter 4 Specifications ...
Страница 161: ...161 Chapter 5 Troubleshooting ...
Страница 169: ...169 Appendix ...
Страница 180: ...180 Appendix MEMO ...