2-48
[Class 6] Special setting
Parametr
No.
Title
Range
Default
Unit
Attribute
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
INI RO
P S T F
6
00
*
Analog torque feed forward conversion
gain
0 to 100
0
0.1V/100%
P S
T
F
4-51
6
02 Velocity deviation excess setup
0
to
20000
0
r/min
P
S T F
6
04 JOG trial run command speed
0 to 500
300
r/min
P S T F
6
05
*
Position 3rd gain valid time
0 to 10000
0
0.1ms
P
S T
F
6
06 Position 3rd gain scale factor
50 to 1000
100
%
P
S T
F
6
07 Torque command additional value
−100 to 100
0
%
P S T F
6
08 Positive direction torque compensation
value
−100 to 100
0
%
P S T F
4-52
6
09 Negative direction torque compensation
value
−100 to 100
0
%
P S T F
6
10 Function expansion setup
0 to 63
0
−
P S T F
6
11
Current response setup
50 to 100
100
%
P S T F
6
13 Current response setup
0 to 10000
250
%
P S T F
6
14 Emergency stop time at alarm
0 to 1000
200
1ms
P S T F
4-53
6
15 2nd over-speed level setup
0 to 20000
0
r/min
P S T F
6
16
For manufacturer's use
−
0
−
P S T F
6
17 Front panel parameter writing selection
0 to 1
0
−
P S T F
6
18
*
Power-up wait time
0 to 100
0
0.1s
P S T F
6
19 Encoder Z phase setup
0 to 32767
0
pulse
P S T F
6
20 Z-phase setup of external scale
0 to 400
0
μs
P S T
F
4-54
6
21 Serial absolute external scale Z phase
setup
0 to 2
28
0
pulse
P S T
F
6
22 A, B phase external scale pulse output
method selection
0 to 1
0
−
P S T
F
6
23 Disturbance torque compensating gain
−100 to 100
0
%
P S
T F
6
24
*
Disturbance observer filter
10 to 2500
53
0.01ms
P S
T F
6
27 Alarm latch time selection
0 to 10
5
s
P S T F
6
31 Real time auto tuning estimation speed
0 to 3
1
−
P S T F
4-55
6
32 Real time auto tuning custom setup
−32768 to 32767
0
−
P S T F
6
33 For manufacturer's use
−
1000
−
P S T F
4-57
6
34
*
Hybrid vibration suppression gain
0 to 30000
0
0.1/s
P S T
F
6
35
*
Hybrid vibration suppression filter
0 to 6400
10
0.01ms
P S T
F
6
37
*
Oscillation detecting level
0 to 1000
0
0.1%
P S T F
6
38 Alarm mask setup
−32768 to 32767
4
−
P S T F
6
39 For manufactuer's use
−
0
−
P S T F
* Definition of symbols under “Attribute” - INI: turning on of power supply is required, RO: read only
*
Definition of symbols under “Related mode” - P: position control, S: velocity control, T: torque control, F: full closed control
13. Setup of Parameter and Mode
List of Parameters
Caution
Note
The symbol “
*
” attached to a parameter No. indicates that the digits of setting unit will
change if the parameter is set by using the setup support software PANATERM.
Parameter describes of this page is P.4-51 to P.4-57.
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...