1. Conformance to international standards
Composition of Peripheral Equipments
Surge Absorber
Option part No.
Voltage specifications
for driver
Manufacturer’s
part No.
Manufacturer
DV0P1450
3-phase 200V
RAV-781BXZ-4
Okaya Electric Ind.
DV0P4190
Single phase 100V/200V
RAV-781BWZ-4
Okaya Electric Ind.
Noise Filter for Signal Lines
Option part No.
Manufacturer’s
part No.
Manufacturer
DV0P1460
ZCAT3035-1330
TDK Corp.
Residual current device
Install a type B Residual current device (RCD) at primary side of the power supply.
Grounding
(1) Connect the protective earth terminal ( ) of the driver and the protective earth ter-
minal (PE) of the control box without fail to prevent electrical shocks.
(2) Do not make a joint connection to the protective earth terminals ( ). 2 terminals are
provided for protective earth.
Note
For driver and applicable peripheral equipments, refer to P.2-6 "Driver and List of Applicable
Peripheral Equipments".