4-43
1
Before
Using
the
Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When
in
Trouble
7
Supplement
Pr5.00
Title
2nd numerator of electronic gear
Related
control mode
P
S T
F
Range
0 to 2
30
Unit
—
Default
0
Pr5.01
Title
3rd numerator of electronic gear
Related
control mode
P
S T
F
Range
0 to 2
30
Unit
—
Default
0
Pr5.02
Title
4th numerator of electronic gear
Related
control mode
P
S T
F
Range
0 to 2
30
Unit
—
Default
0
Set the 2nd to 4th numerator of division/multiplication operation made according to the
command pulse input.
This setup is enabled when Pr0.08 command pulse counts per one motor revolution = 0.
When the setup value is 0, the numerator is replaced by the encoder resolution.
Pr5.03
*
Title
Denominator of pulse output division
Related
control mode
P S T F
Range
10 to 262144
Unit
—
Default
0
For details, refer to P.4-9 Pr0.11.
Pr5.04
*
Title
Over-travel inhibit input setup
Related
control mode
P S T F
Range
0 to 2
Unit
—
Default
1
Set up the operation of the run-inhibition (POT, NOT) inputs.
Setup value
Operation
0
POT
Inhibit positive direction travel
NOT
Inhibit negative direction travel
1
Disable POT, NOT
2
POT or NOT input activates Err38.0 Run-inhibition input protection.
Pr5.05
*
Title
Sequence at over-travel inhibit
Related
control mode
P S T F
Range
0 to 2
Unit
—
Default
0
When Pr5.04 Over-travel inhibition = 0, specify the status during deceleration and stop after
application of the over-travel inhibition (POT, NOT).
<Details of Pr5.05 (Sequence at over-travel inhibit)>
Pr5.04 Pr5.05
During deceleration
After stalling
Deviation counter
content
0
0
Dynamic brake
action
Torque command=0
towards inhibited direction
Hold
1
Torque command=0
towards inhibited direction
Torque command=0
towards inhibited direction
Hold
2
Emergency stop
Torque command=0
towards inhibited direction
Clears before/
after deceleration
4
1. Details of parameter
Setup
[Class 5] Enhancing setting
Note
Related page
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.3-30... “Inputs and outputs on connector X4” • P.6-3 “Protective Function”
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...