![Panasonic MINAS A5-series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/panasonic/minas-a5-series/minas-a5-series_operating-instructions-manual_3706674040.webp)
2-4
Power Supply
100V type : Single phase, 100V +10% to 120V +10% 50/60Hz
(A to C-frame)
–15%
–15%
200V type : Single/3-phase, 200V +10% to 240V +10% 50/60Hz
(A to D-frame)
–15%
–15%
200V type : 3-phase,
200V +10% to 230V +10% 50/60Hz
(E, F-frame)
400V type : 3-phase,
380V +10% to 480V +10% 50/60Hz
–15%
–15%
(1) This product is designed to be used in over-voltage category (installation category) III
of EN 61800-5-1:2007.
(2) Use an insulated power supply of DC12 to 24V which has CE marking or complies
with EN60950.
Circuit Breaker
Install a circuit breaker which complies with IEC Standards and UL recognized (Listed
and
marked) between power supply and noise filter.
The short-circuit protection circuit on the product is not for protection of branch circuit.
The branch circuit should be protected in accordance with NEC and the applicable local
regulations in your area.
Noise Filter
Remarks
Option part No.
Voltage specifications
for driver
Manufacturer’s
part No.
Applicable
driver (frame)
Manufacturer
DV0P4170
Single phase 100V/200V
SUP-EK5-ER-6
A and B-frame
Okaya Electric Ind.
DV0PM20042
3-phase 200V
3SUP-HU10-ER-6
A, B-frame
Single phase 100V/200V
3-phase 200V
C-frame
DV0P4220
Single/ 3-phase 200V
3SUP-HU30-ER-6
D-frame
DV0PM20043
3-phase 200V
3SUP-HU50-ER-6
E-frame
DV0P3410
3-phase 200V
3SUP-HL50-ER-6B
F-frame
• Recommended components
Model No.
Voltage specifications
for driver
Applicable driver
(frame)
Manufacturer
RTHN-5010
3-phase 200V
A, B, C-frame
TDK-Lambda Corp.
RTHN-5030
D-frame
RTHN-5050
E, F-frame
• Select a noise filter whose capacity is commensurate with the power source capacity (in
consideration of the load condition).
•
For the detailed specifications of each noise filter, contact the manufacturer.
2
Preparation
1. Conformance to international standards
Composition of Peripheral Equipments
Remarks
Related page
When performing withstand voltage test of machine and equipment, be sure to remove the
surge absorber; otherwise, it will be damaged.
• P.2-6 “Driver and List of Applicable Peripheral Equipments”
• P.7-77 “Option”
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...