2-12
Compose the circuit so that the main circuit power will be shut off when an error occurs.
In Case of Single Phase, A to D-frame, 100 V / 200 V type
Noise filter
Noise filter
Motor
37
ALM+
L2
L3
L1C
L2C
B1
MC
MCCB
B3
B2
U
V
W
L1
ALM−
External regenerative resistor
Remove the short wire when you connect
the external regenerative resistor.
(C, D-Frame)
External regenerative resistor
36
L
ON
DC12 to 24V
(±5%)
Motor
37
ALM+
L2
L3
L1C
L2C
B1
MC
MCCB
ALM
OFF
B3
B2
U
V
W
L1
Coil surge suppression units
Built-in thermostat of
an external regenerative
resistor (light yellow)
Built-in thermostat of
an external regenerative
resistor (light yellow)
ALM−
Red
White
Black
Green or Green/Yellow
Red
White
Black
Green or Green/Yellow
XA
XB
X4
36
L
ON
MC
DC12 to 24V
(±5%)
ALM
ALM
OFF
MC
ALM
Main power
supply
Control power
supply
Motor
connection
Main power
supply
Control power
supply
Motor
connection
Power supply Single phase, 100V to 120V
+10%
–15%
+10%
–15% Single phase, 200V to 240V
+10%
–15%
+10%
–15%
Power supply 3-phase, 200V to 240V
+10%
–15%
+10%
–15%
Use a reactor for
3-phase
XA
XB
X4
When you use single phase,
connect the main power
between L1 and L3 terminals.
Coil surge suppression units
Remarks
Remove the short wire when you connect
the external regenerative resistor.
(C, D-Frame)
* These colors
are used for
optional cable.
* These colors
are used for
optional cable.
In Case of 3-Phase, A to D-frame, 200 V type
2
Preparation
2.
System Configuration and Wiring
Wiring Diagram (Connector type)
Related page
• P.2-18 “Specifications of Motor connector”
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...