2-14
P.2-16
Short circuit wire
(B2-B3)
B1
B2
L3
L2
L1
L2C
L1C
Ground
(earth)
Protective
earth
terminals
Charg lamp
(Red LED)
*1
Junction cable
for brake
DC Power supply for brake
DC24V
(to be supplied by customer)
Junction cable for motor
Junction cable
for encoder
: High voltage
U-phase(red)
V-phase(white)
W-phase(black)
Regenerative resistor (optional)
• When you use an external regenerative
resistor, install an external protective
apparatus, such as thermal fuse without fail.
• Thermal fuse and thermostat are built in to the
regenerative resistor (Option). If the thermal
fuse is activated, it will not resume.
• Mount the regenerative resistor on
incombustible material such as metal.
Remarks
• Wiring of Main
Circuit Breaker (MCCB)
To protect power supply line from
overloading, install a wiring circuit
breaker rated to the capacity of the
power supply.
Noise Filter (NF)
Removes external noise from the
power lines. And reduces an effect
of the noise generated by the servo
driver.
Magnetic Contactor (MC)
Turns on/off the main power of the
servo driver.
Use coil surge suppression units
together with this.
•
Never start nor stop the servo
motor with this Magnetic Con-
tactor.
Reactor (L)
Reduces harmonic current of the
main power.
Mains
Residual
current device
*1 Do not make displacement, wiring or inspection
while the LED is lit - cause of electric shock.
• Monitor output
Wiring to Connector, X7
P.2-29
PC (to be supplied
by customer)
Setup support software “PANATERM”
Please download from our web site.
• Connection to PC or host controller
• Connection to RS232, RS485
or host controller
• Connection to Safety by-pass plug
• Connection to encoder
• Connection to feedback scale
• Connection to host controller
Wiring to Connector, X6
P.2-26
Wiring to Connector, X5
P.2-24
Wiring to Connector, X4
P.2-23
Wiring to Connector, X3
P.2-22
Wiring to Connector, X2
P.2-20
Wiring to Connector, X1
P.2-20
• Wiring of the Main Circuit
Pin B1, B2 and B3
• B1 and B2 to be kept shorted for
normal operation.
• When you connect an external
regenerative resistor, disconnect
a short bar between B1 and B2,
then connect the external regen-
erative resistor between P and
B2, set up Pr0.16 to 1 or 2.
Pin NC
• Do not connect anything.
Connection with input
power supply
Connection to external
components
Connection to motor driving
phase and ground
P.2-16
P.2-16
* These colors are
used for optional
cable.
Connecting Example of F-frame
2
Preparation
2.
System Configuration and Wiring
Overall Wiring (Terminal block type)
Note
Related page
This overall wiring diagram is a typical one. The pages that follow show wiring for specific
application.
• P.2-8 “Overall wiring (connector type)” • P.7-72 “Options”
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...