4. Inputs and outputs on connector X4
Input Signal and Pin No.
Control Input
Control signal having the desired function can be applied to any input pin of I/F connector.
The logic can be changed.
• Default assignment
Applicable
parameter
Default
parameter
setting
( ): decimal
notation
Default Setup
Position/ Full-closed control
Verocity control
Torque control
Signal
Logic
*
1
Signal
Logic
*
1
Signal
Logic
*
1
Pin
No.
8
Title of
signal
SI1 input
Pr4.00 00828282h
(8553090)
NOT
b-contact
NOT
b-contact
NOT
b-contact
Symbol
SI1
Pin
No.
9
Title of
signal
SI2 input
Pr4.01 00818181h
(8487297)
POT
b-contact
POT
b-contact
POT
b-contact
Symbol
SI2
Pin
No.
26
Title of
signal
SI3 input
Pr4.02 0091918Ah
(9539850) VS-SEL1 b-contact
ZEROSPD
b-contact
ZEROSPD
b-contact
Symbol
SI3
Pin
No.
27
Title of
signal
SI4 input
Pr4.03 00060606h
(394758)
GAIN
a-contact
GAIN
a-contact
GAIN
a-contact
Symbol
SI4
Pin
No.
28
Title of
signal
SI5 input
Pr4.04 0000100Ch
(4108)
DIV1
b-contact
INTSPD3
b-contact
—
—
Symbol
SI5
Pin
No.
29
Title of
signal
SI6 input
Pr4.05 00030303h
(197379)
SRV-ON
a-contact
SRV-ON
a-contact
SRV-ON
a-contact
Symbol
SI6
Pin
No.
30
Title of
signal
SI7 input
Pr4.06
00000f07h
(3847)
CL
a-contact
INTSPD2
a-contact
—
—
Symbol
SI7
Pin
No.
31
Title of
signal
SI8 input
Pr4.07 00040404h
(263172)
A-CLR a-contact A-CLR a-contact A-CLR a-contact
Symbol
SI8
Pin
No.
32
Title of
signal
SI9 input
Pr4.08 00050505h
(328965)
C-MODE
a-contact
C-MODE
a-contact
C-MODE
a-contact
Symbol
SI9
Pin
No.
33
Title of
signal
SI10 input
Pr4.09 00000E88h
(3720)
INH
b-contact
INTSPD1
b-contact
—
—
Symbol
SI10
Note
• The function depends on parameter setup. Refer to P.4-32, 4-33.
Refer to the next section “Function assignable to general purpose input”.
*
1 Operation of a-contact and b-contact:
a-contact: Input signal disconnected from COM– function disabled (OFF state)
Input signal connected to COM– function enabled (ON state)
b-contact: Input signal disconnected from COM– function enabled (ON state)
Input signal connected to COM function disabled (OFF state)
[—]: No function assigned
Содержание MINAS A5-series
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...