Settings for energy saving
Energy saving
Automatically stopping restarts
[Unattended auto shutoff]
If air conditioning automatically stops at the time set on the timer, but then is started again, this setting
automatically stops the unit again repeatedly at set intervals, so it helps prevent people from forgetting to
turn the air conditioning off.
1
Touch [Energy saving] in “EnergySaving”.
1
2
Touch [Unattended auto shutoff].
z
Enter the identification number (password level 1 or 2) and
the “Unattended auto shutoff” screen is displayed.
2
3
Put a check mark in the “Select” column
(3-1), and touch [Set.] (3-2).
z
The “Setting” dialogue is displayed.
3-
1
3-
2
4
Change the settings.
Item
Explanation
Timer settings
(Start time, End
time)
Set the time slots to automatically stop.
Use
to set the time.
Note
y
You can make the settings extend over
different dates.
For example: 22:00 to 08:00
Continued on next page
When the settings are for closed between 21:00 and 09:00, and
the stop monitoring during closed hours is set to 60-minute
intervals
The “auto shutoff” feature works as many times as necessary during
the closed hours (21:00 to 9:00 the next morning in the example).
Time set for unattended auto shutoff
Return to pick up
something
Leave without
turning off
ON
OFF
Detect
Detect
Detect
60 min.
60 min.
60 min.
AUTO
OFF
Closing time
Opening time
9:00
23:00
22:08
21:00
AUTO
OFF
Manual
ON
Manual
ON