57
OPERATION
Figure 70.
12. If the selected profile includes a lower preheat cycle,
the Digital Readout will display "HeatWave = XXX°"
(set preheat temperature). Check the temperature of
the Heat Wave system (Digital Readout on Heat Wave
power source front panel).
If the Heat Wave is at temperature, press and release
the YES Key. The cycle will now activate and
automatically step through the profile. If the Heat
Wave is not at temperature:
Wait until the Heat Wave reaches set temperature,
then press the YES Key to activate the cycle.
or
Press and release the NO Key, then repeat steps 11 &
12 after the Heat Wave reaches set temperature.
NOTE
Once the cycle is initiated, it can be quickly terminated at any time by
simply pressing the CYCLE Key or Cycle Switch (on handpiece).
13. The unit will now cycle through the programmed profile and display the step (e.g., top preheat, reflow,
soak, cool down), temperature and count down time. At the end of each step in the process, the unit
will sound a beep tone. To alert the operator, when the cycle reaches a point 5 seconds before the end
of the reflow process, a beep tone will sound every 1 second until the end of reflow.
14. During the reflow step, the vacuum will activate automatically before the end of the reflow step as
determined by the profile (5 seconds minimum before end of reflow).
15. If the programmed profile contains a Cool Down step, it will occur immediately after the reflow step.
Allow the Cool Down step to time out
NOTE
Allow sufficient time for the component and PCB to cool to room temperature
before handling.
16. When profile cycle is complete, lift the handpiece from the PCB.