38
OPERATION
MANUAL COMPONENT INSTALLATION CONT'D
8. If using a Single Jet nozzle proceed to step 13.
9. Using the Vacuum Pick Adjust Control on the handpiece, adjust the vacuum
cup to a point where the bottom of the vacuum cup touches the component
body. The component is now held in position with the vacuum cup.
Figure 36.
11. Lower nozzle (with component) to a point where the
component leads/contacts rest gently on or just
above the component land pattern.
NOTE
If component has been prepositioned on
land pattern, lower nozzle to desired height
above PCB. A height of 1-1.5mm (.040-
.060") above the PCB when using Box or
Pattern nozzles is recommended.
12. Ensure that the handpiece is held vertical to the PCB (except with Single Jet nozzles).
13. For Single Jet nozzles, hold the end of the nozzle tube above the rework area at a height and angle
which gives the best results in your particular application.
Figure 35.
10. Using the Vacuum Pick Adjust Control,
adjust the position of the component
to a spacing (depending on component) of
1-1.5mm (.040-.060”) between the bottom
of the component and the bottom of the
nozzle when using a Box or Pattern
nozzle.
to contact a BGA component when using
a V-A-N nozzle.
Содержание PROGRAMMABLE THERMOFLO
Страница 2: ...i MANUAL NO 5050 0420 REV A...
Страница 26: ...21 QUICK START...