61
OPERATION
6. "Lower Preheat Time" is now displayed. A number
depicting the amount of time in seconds is also
displayed on the bottom line of the Digital Readout.
Use the numbered keys to enter the correct number.
Always enter 3 numbers to obtain the desired time.
If entering a figure of less than 100, you must enter a
total of 3 numbers. For example, enter 65 seconds as
065. Press and release the STEP Key.
Figure 76.
Figure 77.
7. "Lower Preheat Temp =" is now displayed. A number
depicting the desired bottom preheat temperature (in
degrees C or F as selected in the Set-Up Mode) is
now displayed on the bottom line of the Digital
Readout. Use the numbered keys to enter the desired
temperature. Always enter 3 numbers (including any
zeroes) to obtain the desired temperature. Press and
release the STEP Key.
NOTE
The minimum time setting for all time parameters, except Vacuum
Release (5 seconds minimum) is 10 seconds. If a lower time is entered,
the setting will change to “10 Sec” when the STEP Key is actuated. Enter
the time desired, then press and release the STEP Key again to continue.