63
OPERATION
Figure 81.
Figure 80.
Figure 82.
10. "Top Preheat Temp" is now displayed. A number
depicting the desired top preheat temperature (in
degrees C or F as selected in the Set-Up Mode) is
now displayed on the bottom line of the Digital
Readout. Use the numbered keys to enter the desired
temperature. Always enter 3 numbers (including any
zeroes) to obtain the desired temperature. Press and
release the STEP Key.
11. "Top Pheat Start Time" is now displayed. This is the
time delay at the beginning of a preheat cycle (the
Lower Preheat, if used, is already on) before the top
preheat begins. A number depicting the amount of
delay ("Start Time") in seconds is now displayed on
the bottom line of the Digital Readout. Use the
numbered keys to enter the correct number (10
seconds minimum). Always enter 3 numbers to
obtain the desired time. Press and release the STEP
Key.
12. "Top Preheat Blower =" is now displayed. A number
depicting the desired blower speed (1-9) is on the
bottom line of the Digital Readout. Use the
numbered keys to enter the desired number. Press
and release the STEP Key.