2 General Description
2-24
Service Manual – Osmetech OPTI™ Analyzer
Sampling Menu – Osmetech OPTI CCA
Fig. 2-12: Sampling Menu
Osmetech OPTI CCA
Rev: ROPX2.24
Osmetech OPTI CCA
Please Wait
Please Wait
Warming up
Purging Gas System XX
Password <ENTER>
Calibrating XXX
Please Wait
Open cover - Wipe and
insert Cass. - close cover
Mix and place the XXX
Sample - Press <ENTER>
Aspirating Sample
Please Wait
Measuring Sample
Power On
Measuring - To input XXX
Pat. Data press <ENTER>
Measurement
Complete
Measuring - To input XXX
Pat. Data press <ENTER>
pH PCO2 PO2 BE
7.245 35.4 89.3 -1.2
Na K Ca++ tCO2
134.5 3.54 1.24 20.9
PO2 tHb SO2 Hct
89.3 15.4 95.6 46.2
For READY press <ESC>
Edit Pat. Data <ENTER>
Please Remove Cassette
Patient Sample
Sex: ? MALE FEMALE
Patient Sample
Temp: 37 'C
Patient Sample
Op. ID: XXXXXXXXXXX
Patient Sample
Pat. ID: XXXXXXXXXXX
Patient Sample
Hb Type: ADULT FETAL
Patient Sample Type: Art
Ven MixVen Cap Cord CPB
Patient Sample
tHb: 15.0 g/dL
Patient Sample
MCHC: 33.3 %
O2 Mode: RmAir Mask T-P
NC Vent Bag Hood Other
Patient Sample
FIO2: 0.21
Patient Sample
RQ: 0.84
Patient Sample
P50: 26.7 mmHg
VentMode:No SIMV PSV PCV
CMV/AC CPAP PCIVR BIPAP
Patient Sample
TVol (VT): 0000 mL
Patient Sample
MVol (VE): 000 L
Patient Sample
PIP: 000
Patient Sample
Pplat: 0.0
Patient Sample
PS: 0.0
Patient Sample
PEEP: 0.0
Patient Sample
I/E Ratio - 1 : 1.0
Patient Sample
Liter Flow: 000 Lpm
Patient Sample
Rate (f): 000 bpm
Patient Sample
CPAP: 00
Patient Sample
BiLev. Press.: 0.0/ 0.0
Patient Sample
User Field: 000000
Patient Sample -Blanking
Blank pH : NO YES
Patient Sample -Blanking
Blank PCO2 : NO YES
Patient Sample -Blanking
Blank PO2 : NO YES
Patient Sample -Blanking
Blank Na+ : NO YES
Patient Sample -Blanking
Blank K+ : NO YES
Patient Sample -Blanking
Blank Ca++ : NO YES
Patient Sample -Blanking
Blank tHb : NO YES
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
ES
C
ES
C
ESC
ESC
ESC
ES
C
ES
C
ESC
ESC
ES
C
ESC
ES
C
ES
C
ESC
ESC
ESC
ESC
ES
C
ES
C
ES
C
ESC
ESC
Enter
Enter
ES
C
Enter
ESC
Enter
ES
C
Enter
ES
C
Enter
ESC
Enter
ESC
Enter
ES
C
Enter
ES
C
Enter
ES
C
Enter
Enter
Enter / ESC
ESC
Enter
Osmetech OPTI CCA
Patient Report
Enter
DATA - Export
Patient SRC Controls
NOT READY: Temp
For Menu press <ENTER>
ESC
Enter
READY Swipe Cass. Barcode
For Menu press <ENTER>
Export Data
Swipe
Cassette
Barcode
RUN: SRC Controls
Data TimeDate Setup Diag
Enter
Enter
NOTES:
1.
Screen available only if Password is configured under Setup- Misc. - Security.
2.
Patient input data is configurable under Setup - Pat.Info - ON/OFF.
3.
Results Blanking is configurable under Setup - Format - Blanking and is
dependent on the cassette type being used.
4.
Screen available only if Auto-Export is configured under Setup - Misc. - Comm.
1
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Enter
4
Patient Sample
User Field2: 000000
ES
C
Enter
Patient Sample
User Field3: 000000
ES
C
Enter
2
2