7.5. Messages on the controller
Pressing START button – the main switch on the control panel – turns on the burner. In the first stage,
lamps and the fan turn on (in order to ventilate the combustion chamber). After the chamber is ready, the
starting dose of fuel (pellet) is feeder and the lighter is turned on. The feeder needs from 90 to 120
seconds to ignite the fuel.
After “identifying the flame” (when the set lightness threshold is detected by the photocell), the lighter is
switched off and the ORTE burner goes into automatic mode. This is signalled by the message MAXIMUM
POWER on the controller display.
When the lightness in the combustion chamber drops to the lower value, the lighter is turned on to re-
ignite the fuel.
The state of device can be evaluated based on the displayed message.
Message displayed on RK-2006LPG or
RK-2006 SPGM
Explanatory notes
TEMPERATURE 67°C
STOP
The controller is switched off
To resume, press START
TEMPERATURE 67°C
INFLAMING
Inflaming takes place
TEMPERATURE 67°C
STANDBY
STANDBY message means that the required temperature has been
reached
TEMPERATURE 67°C
PUTTING OUT
The fireplace is being put out
TEMPERATURE 67°C
MAXIMUM POWER
The burner is working at maximum power in automatic mode (has
not reached the desired temperature)
TEMPERATURE 67°C
MINIMUM POWER
The burner is working at minimum power in automatic mode (has
reached the desired temperature)