Page | 12
3.8. Minimal distances and flammability of construction materials
INFO: Depending on the country, different minimum distances may apply – please consult an installer or
a chimney-sweeper.
No flammable materials allowed in the room.
3.9. Minimal reflux temperature
The boiler must operate with a minimum reflux temperature of 42 ÷ 60 ° C.
Ensure the limit temperature by using appropriate device (mixing valve with pump).
3.10. Tools, materials and auxiliary measures
Installation and maintenance of the boiler require standard tools used by installers of heating and water
systems.
Cleaning tools are delivered along with the boiler.
4. SAFETY
The device must be installed and accepted only by an authorized installer with confirmed qualifications.
The boiler must be installed, placed and used in accordance with applicable regulations. Strictly adhere to
the instructions contained in Technical and Maintenance Documentation. Do not install the boiler in places
at risk of fire, explosion, flooding or freezing. The boiler must be connected to an electrical outlet –
grounded and with a differential protection. The boiler is adapted to an open system, which means that
the hydraulic system must have an open expansion vessel with an overflow pipe.
Unattended minors and pets cannot be near the operating boiler.
Do not exceed maximum power. Ensure proper air circulation – in accordance with appropriate
regulations. Ensure chimney-sweep inspection in accordance with applicable regulations, not less
frequently than once every 3 months or in accordance with local regulations.
Ventilation of the room where the boiler is placed must be made in accordance with applicable
regulations.
In order to operate properly, the boiler needs fresh air and the required chimney draft.
Air should be supplied to the burner in order to carry out proper combustion processes in the boiler
chamber.
Do not connect several heating devices to the same chimney. However, if there are other heating devices
installed in the room (connected to other chimneys), supply sufficient amount of air to ensure combustion
in each device and ensure sufficient air for room ventilation, taking into account all the devices.
It is forbidden to open the device during operation due to the risk of burns.
No flammable materials allowed in the room.
Fuel storage – in accordance with relevant regulations and standards (in a different room than the boiler).
An ABC type powder extinguisher must be placed near the device.
In the event of a chimney fire, immediately put out the burner by pressing the central switch – position 0,
placed above the controller. Do not open the ash pan, cut off all access of air needed for combustion. Do