www.orte.pl
www.orte.pl
Page | 13
not open windows. Then, secure the chimney outlet using the chimney sieve. It is intended to reduce the
intensity of soot combustion in the chimney by suppressing the fire, and to prevent the escape of burning
soot from the chimney, consequently protecting the roofs and nearby buildings against fire. The chimney
sieve can be replaced with a wet cloth to cover the chimney outlet in case of fire. Damp the cloth with
water until the soot is burnt-out. Do not extinguish chimney fire with water, because rapid cooling of the
chimney and water evaporation can cause cracks in the chimney and the spreading of fire.
If the device is operating in adverse weather conditions, e.g. during an unfavourable chimney draft (too
low draft) or bad weather conditions (e.g. cold, strong wind), extinguish the device to avoid the return of
fumes. Before re-igniting the device, wait until weather conditions improve.
In the case of a longer break in operation, perform chimney sweep inspection, because there is a risk of
clogging.
Basic requirements and standards of fire protection in the Republic of Poland applicable in the case of
Pellet Comfort devices:
1)
regulations of the Minister of Internal Affairs and Administration:
on the reconciliation of a construction project in terms of fire safety, of 16 June 2003, Journal of
Laws no 121, item 1137 (amendments – regulation of the Ministry of Internal Affairs and
Administration of 16 July 2009, Journal of Laws no. 119, item 998)
on fire-fighting water supply and access roads, of 24 July 2009, Journal of Laws no. 124, item 1030,
on the fire protection of buildings, other construction works and areas, of 07 June 2010, Journal of
Laws no. 109, item 719,
2)
regulation of the Minister of Infrastructure:
on the technical requirements to be met by buildings and their location, of 12 April 2002, Journal of
Laws no. 75, item 690 with further amendments),
3)
PN-B-02411 Heating. Built-in solid fuel boilers – Requirements.
The owner must strictly comply with the Technical and Maintenance Documentation.
4.1. Safety Tips
General Safety Tips
Failure to follow these instructions can result in serious injuries, including death, and can cause damage to
property and the environment.
Ensure that the system, connection of the flue duct connector, as well as the first start-up,
maintenance and repairs are performed only by an authorized installation company.
Ensure that the installation acceptance is performed by an authorized supervisory body.
Clean the boiler depending on the intensity of use. Follow the frequency of cleaning indicated in the
chapter “Cleaning”. Immediately remove any identified deficiencies.
Perform maintenance at least once a year. During maintenance, check the proper operation of the
entire system. Immediately remove any identified deficiencies.